Parameter assignment and configuration
4.3 Parameter assignment with the device configuration
Communications module RF120C with application blocks for S7-1200 and S7-1500
Operating Instructions, 07/2013, C79000-G8976-C328-01
25
4.3.2.2
RF300
Table 4- 4
RF300 general
Parameter
Parameter value
Default value
Description
Transponder type
RF300
ISO 15693
RF300
Selection of the transponders used.
Table 4- 5
RF380R
Parameter
Parameter value
Default value
Description
RF power
0.50 - 2.00 W
1.25 W
Setting for the output power of the reader.
Transponder type
RF300
ISO 15693
RF300
Selection of the transponders used.
4.3.2.3
RF600
Table 4- 6
RF600 general
Parameter
Parameter value
Default value
Description
Max. no. of transponders
1 - 80
1
Number of transponders expected in the
antenna field.
Permitted values:
•
1 - 40 for RF620R
•
1 - 80 for RF630R with 2 antennas
•
1 - 40 for RF630R with 1 antenna
The value stored in "multitag" defines the
expected number of transponders to be read
(EPC-ID) in the inventory.
The value does not restrict the number of
transponders to be processed in the antenna
field.
To ensure an efficient inventory of
transponders in the antenna field, make sure
that the values specified here do not deviate
by more than approximately 10% from the
maximum number of transponders to be
expected in the antenna field.
Reader type
RF620R ETSI
RF620R FCC
RF620R CMIIT
RF630R ETSI
RF630R FCC
RF630R CMIIT
RF620R ETSI
Selection of the reader used.
By selecting a reader, you open the "Reader
type" menu. This menu is described in the
following section.