background image

Description 

 

2.1 Area of application and features 

 

Communications module RF120C with application blocks for S7-1200 and S7-1500 

8

 

Operating Instructions, 07/2013, C79000-G8976-C328-01 

Features 

To operate the RF120C, you require a SIMATIC S7-1200. 
With the help of the RF120C communications module, you can address the data on the 

transponders physically. This type of addressing is also referred to as normal addressing. 
A Hardware Support Package (HSP) allows you to install the RF120C module later in the 

catalog of the TIA Portal. You can configure and set parameters for modules using the TIA 

Portal. 

Other features 

 

A maximum of three RF120C modules can be operated at the same time with one 

SIMATIC S7-1200. 

 

There are no restrictions relating to operation with other modules from the SIMATIC S7-

1200 range. 

 

Degree of protection IP20 

 

System integration with standard cables 

 

Standardized user interface for Ident technology with easy-to-use function blocks 

Summary of Contents for SIMATIC RF120C

Page 1: ... ___________________ ___________________ SIMATIC Ident RFID systems Communications module RF120C with application blocks for S7 1200 and S7 1500 Operating Instructions 07 2013 C79000 G8976 C328 01 Introduction 1 Description 2 Mounting connecting up and commissioning 3 Parameter assignment and configuration 4 Service and maintenance 5 Technical data 6 Dimension drawings 7 Appendix A Reset function ...

Page 2: ...operated only by personnel qualified for the specific task in accordance with the relevant documentation in particular its warning notices and safety instructions Qualified personnel are those who based on their training and experience are capable of identifying risks and avoiding potential hazards when working with these products systems Proper use of Siemens products Note the following WARNING S...

Page 3: ...er supply 19 3 5 Pin assignment of the socket for the external power supply 20 3 6 Pinout of the D sub socket 20 4 Parameter assignment and configuration 21 4 1 Hardware configuration 21 4 2 Configuration 21 4 3 Parameter assignment with the device configuration 22 4 3 1 Menu Reader 22 4 3 2 Menu Reader System 23 4 3 2 1 RF200 24 4 3 2 2 RF300 25 4 3 2 3 RF600 25 4 3 2 4 SLG D10S 27 4 3 2 5 SLG D1...

Page 4: ...nings 61 5 4 Module replacement 61 6 Technical data 63 7 Dimension drawings 65 A Appendix 67 A 1 Approvals and standards 67 A 1 1 Approvals 67 A 1 2 Standards and test regulations 70 A 2 Connecting cable 72 A 2 1 Routing of standard cables 72 A 2 2 Self assembled cables 75 A 3 Ordering data 76 A 3 1 Ordering data for RF120C 76 A 3 2 Ordering data for SIMATIC S7 1200 accessories 76 A 3 3 Further or...

Page 5: ...if these are connected to an S7 1200 or S7 1500 The Reset function blocks required for these communications modules can be found in the appendix Position in the information landscape In addition to these operating instructions you require the operating instructions SIMATIC S7 1200 programmable controller http support automation siemens com WW view en 36932465 The manual of the particular RFID syst...

Page 6: ...Introduction Communications module RF120C with application blocks for S7 1200 and S7 1500 6 Operating Instructions 07 2013 C79000 G8976 C328 01 ...

Page 7: ... used as central I O in a SIMATIC S7 1200 Figure 2 1 RF120C communications module When operating the communications modules with a SIMATIC S7 1200 there is a global library with function blocks available to you Only one reader or one code reading device with an RS 422 interface can be operated with an RF120C communications module RFID readers and code readers from the following product families ca...

Page 8: ...is also referred to as normal addressing A Hardware Support Package HSP allows you to install the RF120C module later in the catalog of the TIA Portal You can configure and set parameters for modules using the TIA Portal Other features A maximum of three RF120C modules can be operated at the same time with one SIMATIC S7 1200 There are no restrictions relating to operation with other modules from ...

Page 9: ... S7 1200 is designed for panel or rail mounting and consists of the following components SIMATIC S7 1200 Power supply unit Up to 3 communications modules CM e g RF120C Up to 8 signal modules SM You can thus set the focus of your configuration on local requirements The simple handling of the SIMATIC S7 1200 ensures fast commissioning and user friendly maintenance RF120C communications module CPU SI...

Page 10: ...up with various SIMATIC Ident communications modules 2 3 Integration Integration The figure below shows how the SIMATIC S7 1200 with SIMATIC RF120C is integrated into an automation system Figure 2 4 Example of integrating a SIMATIC S7 1200 with RF120C The RF120C is integrated in the SIMATIC S7 1200 hardware configuration using an HSP Following this the RF120C can be configured in the TIA Portal us...

Page 11: ...oltage The equipment is designed for operation with Safety Extra Low Voltage SELV by a Limited Power Source LPS This does not apply to 100 V 240 V devices This means that only SELV LPS complying with IEC 60950 1 EN 60950 1 VDE 0805 1 must be connected to the power supply terminals The power supply unit for the equipment power supply must comply with NEC Class 2 as described by the National Electri...

Page 12: ...romagnetic pulses Make sure that any cables liable to lightning strikes are fitted with suitable overvoltage protection 3 2 Installing and commissioning the RF120C Prior to installation and commissioning WARNING Read the system manual S7 1200 Programmable Controller Prior to installation connecting up and commissioning read the relevant sections in the system manual S7 1200 Programmable Controller...

Page 13: ...10 mm 55 mm Signal modules Width depends on the signal module being used 45 mm 22 5 mm 70 mm 35 mm Communications interfaces e g RF120C 30 mm 15 mm Width B The distance between the edge of the housing and the center of the hole in the DIN rail mounting clip DIN rail mounting clips All CPUs SMs CMs and CPs can be installed on the DIN rail in the cabinet Use the pull out DIN rail mounting clips to s...

Page 14: ...at the permitted temperature ranges depend on the position of the installed device Device position permitted temperature range Installation location Horizontal installation of the rack 0 C to 55 C Vertical installation of the rack 0 C to 45 C NOTICE Connection with power off Wire up the SIMATIC S7 1200 and modules to be connected only when the power is off Note Power supply from the power outputs ...

Page 15: ...ly unit 5 Secure the wires of the external power supply to the plug supplied with the RF120C and insert the plug in the socket on the top of the RF120C The pinning is shown beside the socket on the top of the housing You will also find this in the section Pin assignment of the socket for the external power supply Page 20 6 Connect the reader using the RF120C cable to the D sub female connector of ...

Page 16: ... 2013 C79000 G8976 C328 01 Table 3 3 Dismantling an RF120C Task Procedure 1 Make sure that the CPU and all S7 1200 devices are disconnected from the electric power 2 Remove the two plug in connectors from the CPU and the RF120C 3 Pull out the two DIN rail clamps on the CPU and the RF120C 4 Remove the CPU and the RF120C from the DIN rail 5 Hold the CPU and RF 120 firmly and pull them apart ...

Page 17: ...d version of the connecting cable is available in lengths 2 m 5 m and 10 m Figure 3 2 Opening the doors in the housing of the RF120C To connect the cable open the lower door in the housing as shown in the figure and connect the reader using the D sub cable and the 9 pin D sub socket of the communications module At the top right behind the upper door in the housing of the module the version is prin...

Page 18: ...tions module RF120C with application blocks for S7 1200 and S7 1500 18 Operating Instructions 07 2013 C79000 G8976 C328 01 Diagnostics LEDs Bus connector for connection to the controller D sub socket for connecting the reader Figure 3 3 Sockets and LEDs of the RF120C communications module ...

Page 19: ...op of the module The reader is supplied with voltage via this power supply The matching plug with screw terminals ships with the product If there is overload the RF120C turns off the power supply to the reader and signals this to the CPU Mounted terminal block for the 24 VDC power supply of the reader Figure 3 4 Terminal block for the 24 VDC power supply The RF120C is supplied with power via the b...

Page 20: ...r the external power supply Figure 3 5 Socket for the external 24 VDC power supply view from above Table 3 4 Pin assignment of the socket for the external power supply Pin Labeling Function 1 L 24 VDC max 1 A 2 M Ground reference for 24 VDC 3 Ground connector 3 6 Pinout of the D sub socket RS 422 interface Table 3 5 Pinout of the D sub socket Pin Description Pin Description 1 24 VDC 6 RxD 2 not us...

Page 21: ... on the Internet on Support homepage http www siemens com automation service support After installation you can locate the RF120C module on the following path in the device configuration SIMATIC S7 1200 Communications modules Ident Systems RF120C 6GT2002 0LA00 4 2 Configuration Configuration with the TIA portal You configure the RF120C is using the TIA Portal To do this drag the RF120C to the devi...

Page 22: ...ppendix B This means that no further parameter assignment in the program is required for the RFID readers when working with the RF120C For reasons of compatibility with the communications modules RF180C and ASM 456 you also have the alternative of setting parameters for the RF120C using special Reset blocks see Appendix B The Parameter main menu item is divided into the following two menus Reader ...

Page 23: ...r alarms are generated Hard errors Extended alarms are generated if the following events occur Hardware fault memory test Firmware error checksum Connection to reader lost Short circuit fault interruption if supported by the hardware You will find more detailed information on diagnostics in the section Diagnostics Page 49 4 3 2 Menu Reader System Menu Reader System In this menu you can set all spe...

Page 24: ...a field of the reader Off RF field on the presence check in the FB is suppressed The antenna on the reader is nevertheless turned on as long as it has not been turned off by a command Off RF field off the antenna is turned on only when a command is sent and it then turns itself off again RF300 only Reset ERR LED On Off Off On the flashing of the error LED on the RF120C is reset by each FB reset Of...

Page 25: ...lue Default value Description Max no of transponders 1 80 1 Number of transponders expected in the antenna field Permitted values 1 40 for RF620R 1 80 for RF630R with 2 antennas 1 40 for RF630R with 1 antenna The value stored in multitag defines the expected number of transponders to be read EPC ID in the inventory The value does not restrict the number of transponders to be processed in the anten...

Page 26: ...s with EPC ID of any length Intelligent Single Tag Mode ISTM On Off Off Enable disable the Intelligent Single Tag Mode ISTM algorithm 1 Black list On Off Off Enable disable the Black list 1 Radiated power internal antenna RF620R 0 B 4 Setting the radiated power for the internal antenna 1 2 With the RF620R either only the internal or only the external antenna can be set Transmit power external ante...

Page 27: ... 1 4 9 A B F 18 63 19 79 22 158 27 501 27 501 27 501 18 63 19 79 22 158 27 501 28 631 29 794 20 100 21 126 24 251 29 794 30 1000 31 1259 18 65 19 79 22 158 27 501 28 631 29 794 18 63 19 79 22 158 27 501 27 501 27 501 4 3 2 4 SLG D10S Table 4 9 SLG D10S Parameter Parameter value Default value Description RF power 0 50 10 00 W 1 00 W Setting for the output power of the reader Transponder type ISO I ...

Page 28: ...e time in the antenna field BERO mode Without BEROs 1 or 2 BEROs 1st BERO on 2nd BERO off Synchronization by cable connection Without BEROs Without BEROs no reader synchronization 1 or 2 BEROs the BEROs are logically ORed The antenna field is turned on during the actuation of a BERO 1st BERO on 2nd BERO off The 1st BERO turns on the antenna field and the 2nd BERO turns the antenna field off If the...

Page 29: ...00000000 00000000 Expert mode With this function you can specify the reset parameters directly in hexadecimal notation This setting may only be selected if you have previously received the hex string for the setting from a member of the SIEMENS staff 4 3 2 8 Parameters via FB MV code reader Table 4 13 Parameters via FB MV code reader Parameter Parameter value Default value Description MOBY mode RF...

Page 30: ...ctions are available so that the communication with the Ident systems can be programmed as simply as possible Read Write Read_EPC ID Write_EPC ID Set_Ant PLC data type HW_CONNECT_VAR Separate data type for all Ident application blocks for physical addressing of communications modules and readers and for synchronizing the function blocks used for each reader Function block AdvancedCmd Advanced comm...

Page 31: ... DWORD INT Figure 4 4 Example of an FB Input parameters EN Enabling Input EXECUTE There must be a positive edge at this input before the block will execute the command HW_CONNECT Global variable to address the reader channel and to synchronize the application blocks This variable needs to be created and addressed once for each connected RF120C HW_CONNECT must always be transferred to the function ...

Page 32: ...if the ERROR bit was set PRESENCE Bool This bit indicates the presence of a transponder The displayed value is updated each time the block is called ENO Enable output General sequence when calling function blocks Case By setting EXECUTE EXECUTE 1 the function instruction is started If the job was completed successfully DONE 1 you need to reset EXECUTE Case EXECUTE is set for only one cycle As soon...

Page 33: ... the HW_CONNECT_VAR variable 2 Click on the triangle in front of the Connect entry to open the structure it contains 3 With the help of the parameters in the Address structure you can set the addresses for the RF120C to be used HW_ID Hardware identifier of the module CM_CHANNEL Channel of the interface module With the RF120C the value is always 1 because the CM only has one channel With RF180C or ...

Page 34: ...O addresses tab you will find the I O address that corresponds to LADDR Remember that the input and output address must have the same value 4 On the General RF120C RS422 Hardware identifier tab you will find the hardware identifier that corresponds to the HW_ID Figure 4 8 The Hardware identifier parameter How the FBs work You can only ever send one command to an RF120C You can however call and sta...

Page 35: ...om the library and insert it in your own program before you start to select and program the function blocks 4 4 1 Reset_Reader With the Reset_Reader FB all SIEMENS RFID reader types can be reset All the readers are reset to the settings stored in the device configuration of the RF120C The Reset_Reader FB has no specific parameters The execution of the FB is started by the EXECUTE parameter You wil...

Page 36: ... job Figure 4 10 Read function block Table 4 15 Explanation of the Read function block Parameter Data type Description ADR_TAG WORD Physical address on the transponder where the read starts You will find more detailed information on addressing in the section Transponder addressing Page 40 LEN_DATA INT Length of the data to be read 1 1024 bytes UID Array 1 8 of Byte Unique Identifier of the transpo...

Page 37: ...igure 4 11 Write function block Table 4 16 Explanation of the Write function block Parameter Data type Description ADR_TAG WORD Physical address on the transponder where the write starts You will find more detailed information on addressing in the section Transponder addressing Page 40 LEN_DATA INT Length of the data to be written 1 1024 bytes UID Array 1 8 of Byte Unique Identifier of the transpo...

Page 38: ...lock is intended only for single tag mode Figure 4 12 Read_EPC ID function block Table 4 17 Explanation of the Read_EPC ID function block Parameter Data type Description LEN_DATA INT Length of the EPC ID to be read out 1 62 bytes IDENT_DATA Array 1 1024 of Byte Data buffer in which the read EPC ID is stored 4 4 5 Write_EPC ID The Write_EPC ID block overwrites the EPC ID of the RF600 transponder Th...

Page 39: ...ngth of the EPC ID to be written 1 62 bytes IDENT_DATA Array 1 1024 of Byte Data buffer with the EPC ID to be written 4 4 6 Set_Ant With the Set_Ant block antennas can be turned on or off There are different function blocks for RF300 and RF600 The Set_Ant_RF300 block can also be used for RF200 and MOBY U Set_Ant_RF300 Figure 4 14 Set_Ant_RF300 function block Table 4 19 Explanation of the Set_Ant_R...

Page 40: ...2 Bool 0 turn antenna 2 off 1 turn antenna 2 on TAGLIST_INIT Bool 0 TagList is reset 1 the existing TagList continues to be used 4 5 Transponder addressing Addressing The data memories are addressed linearly from address 0000 or the specified start address to the end address The CM or reader automatically recognizes the size of the memory on the transponder If the end address on the transponder is...

Page 41: ...d as a whole Start address Length FFF0 0008 16 8 ISO MDS I Code SLI 112 bytes Start address End address 0000 006F 0 111 ID no fixed coded can only be read as a whole Start address Length FFF0 0008 16 8 ISO MDS Tag it HF I 256 bytes Start address End address 0000 00FF 0 255 ID no fixed coded can only be read as a whole Start address Length FFF0 0008 16 8 ISO MDS my d SRF55V10P 992 bytes Start addre...

Page 42: ...ROM user memory for RF300 can be used either as R W memory or as an OTP memory see RF300 system manual Start address End address FF00 FF13 256 237 R W memory FRAM Start address End address 0000 1FFC 0 8188 ID no fixed coded can only be read as a whole Start address Length FFF0 0008 16 8 32 KB data memory FRAM EEPROM R W or OTP memory EEPROM The EEPROM user memory for RF300 can be used either as R ...

Page 43: ...the meaning of the OTP memory RF300 tags and ISO tags have a memory area that can be protected against overwriting This memory area is called OTP Five block addresses are available for activating the OTP function FF80 FF84 FF88 FF8C and FF90 A write command to this block address with a valid length 4 8 12 16 20 depending on the block address protects the written data from subsequent overwriting No...

Page 44: ...d via the R W address or the OTP address R W EEPROM Write RF300 OTP once Address Length Address Length FF00 1 20 FF80 4 8 12 16 20 FF01 1 19 FF02 1 18 FF03 1 17 FF04 1 16 FF84 4 8 12 16 FF05 1 15 FF06 1 14 FF07 1 13 FF08 1 12 FF88 4 8 12 FF09 1 11 FF0A 1 10 FF0B 1 9 FF0C 1 8 FF8C 4 8 FF0D 1 7 FF0E 1 6 FF0F 1 5 FF10 1 4 FF90 4 FF11 1 3 FF12 1 2 FF13 1 Note Write access to addresses starting at FF80...

Page 45: ... write FFC0 FFC7 FF80 FF87 yes yes RF680L NXP G2XM 00 3F FF00 FF1D 96 bits FF00 FF0B read write FFC0 FFC7 FF80 FF87 yes yes RF610T NXP G2XM 00 3F FF00 FF1D 96 bits FF00 FF0B read write FFC0 FFC7 FF80 FF87 LOCKED yes RF610T ATEX NXP G2XM 00 3F FF00 FF1D 96 bits FF00 FF0B read write FFC0 FFC7 FF80 FF87 LOCKED yes RF620T Impinj Monza 4QT 1 00 3F FF00 FF0F 96 bits FF00 FF0B read write FFC0 FFC9 FF80 F...

Page 46: ...ddress 0000 07FF 0 2047 Read OTP memory write access only possible once The OTP memory of MOBY U can only be processed completely i e the start address must always be specified with value FFF0 hex and the length with value 10 hex Start address Length FFF0 10 16 16 ID no 4 fixed coded bytes can only be read with the MDS status command 32 KB data memory Start address End address 0000 7FFF 0 32767 Re...

Page 47: ...ocated behind the upper door in the housing Open the upper door in the housing by pulling it down To allow this the doors in the housing are extended to form a handle Figure 5 1 The LEDs of the RF120C LED display of the module The module has various LEDs for displaying the status LED on the front panel The DIAG LED that is always visible shows the basic statuses of the module LEDs below the upper ...

Page 48: ... Error messages Page 52 Note LED colors when the module starts up When the module starts up all its LEDs are lit for a short time Multicolored LEDs display a color mixture At this point in time the color of the LEDs is not clear Display of the operating and communication status The LEDs indicate the operating and communications status of the module according to the following scheme Table 5 2 Displ...

Page 49: ...ction LED status display on the RF120C Page 47 STEP 7 Basic Professional using the TIA Portal Diagnostics functions in the Online diagnostics menu Here you can obtain static information on the selected module General information on the module Diagnostics status Evaluation with the standard GET_DIAG instruction Evaluation based on the ERROR and STATUS output parameters You will find more detailed i...

Page 50: ...ions module RF120C with application blocks for S7 1200 and S7 1500 50 Operating Instructions 07 2013 C79000 G8976 C328 01 Figure 5 2 Diagnostics view in the TIA Portal General entry Figure 5 3 Diagnostics view in the TIA Portal Diagnostic status entry ...

Page 51: ...ation backplane bus PROFINET PROFIBUS E1 transponder related error E2 error on the air interface E4 reader hardware fault E5 error in the communication between reader and FB E6 error in the user command E7 error message generated by the FB Byte 1 Error numbers This byte defines the meaning of the error code and the warnings The error numbers have the followinig meaning 0x00 no error no warning 0x8...

Page 52: ...rors that have occurred 1x E4 FE 07 No error Communications module has started up and is waiting for an init_run 3x E4 FE 03 Error in the connection to the reader the reader is not answering 5x E6 FE 01 unknown command all product families incorrect parameter assignment RF600 only 17x E4 FE 01 Short circuit or overload 18x E4 FE 8D Internal communication error of the communications module 19x E4 F...

Page 53: ...just left the antenna field contains an incomplete data record Operating distance from reader to transponder is not being maintained Configuration error The data record to be processed is too large in dynamic mode With timeout No transponder in the antenna field E1h FEh 03h Address error The address area of the transponder has been exceeded Starting address of the command start has been incorrectl...

Page 54: ... attempts The transponder is positioned exactly in the limit area of the transmission window Data transmission to the transponder is being affected by external interference CRC sending error The transponder reports CRC error frequently transponder is positioned in the limit area of the reader transponder and or reader has a hardware defect Only during initialization CRC error on receipt of acknowl...

Page 55: ...not on or has failed briefly Automatic fuse on the communications module has blown Hardware defect There is another reader in the vicinity and is this is active Execute init_run after error correction The antenna of the reader is turned off A tag command to the communications module was started in this status Turn on the antenna with the command antenna on off The antenna is turned on off and has ...

Page 56: ...he bus The backplane bus PROFIBUS or PROFINET may have been reconfigured e g with HW Config E4h FEh 8Dh Internal communication error of the communications module Connector contact problem on the communications module Hardware of the communications module has a defect Send in communications module for repair Start init_run command after error correction Internal monitoring error of the communicatio...

Page 57: ...ement message frames TDB DBN E5h FEh 0Ch Synchronization error incorrect increment of AC_H AC_L and CC_H CC_L in the cyclic control word INIT had to be executed E6h FEh 01h Unknown command Ident profile transfers an uninterpretable command to the communications module The AdvancedCmd block was supplied with an incorrect CMD The CMD input of the AdvancedCmd block was overwritten by the user The tra...

Page 58: ...s in the WRITE CONFIG command Start init_run command after error correction Check the HW_CONNECT parameter E6h FEh 06h The timer for Reset_Reader has elapsed E7h FEh 01h In this state only the Reset_Reader command is permitted E7h FEh 02h The CMD command code is not permissible E7h FEh 03h The length parameter of the command is too long It does not match the global data reserved in the send data b...

Page 59: ...r code indicates that parameter x is in a range that not allowed for the system function Cxh 8xh 25h Area error when writing a parameter This error code indicates that parameter x is in a range that is not allowed for the system function Cxh 8xh 26h Parameter contains a time cell number which is too high Cxh 8xh 27h Parameter contains a counter cell number which is too high Cxh 8xh 28h Alignment e...

Page 60: ...ct Cxh 80h B0h SFC not possible for module type Data record unknown to module Data record number 241 is not allowed Data records 0 and 1 are not permitted for SFC 58 WR_REC Cxh 80h B1h The length specified in the RECORD parameter is wrong Cxh 80h B2h The configured slot is not occupied Cxh 80h B3h Actual module type is not the module type specified in SDB1 Cxh 80h C0h RDREC The module has the data...

Page 61: ...s has the value Fxh or Dxh No warnings are indicated with the RF120C 5 4 Module replacement The configuration data of the RF120C is stored on the local CPU When necessary this allows simple replacement of this communications module without needing to re load the project data on the module When the CM starts up again the CPU automatically transfers the stored data to the CM You will find informatio...

Page 62: ...Service and maintenance 5 4 Module replacement Communications module RF120C with application blocks for S7 1200 and S7 1500 62 Operating Instructions 07 2013 C79000 G8976 C328 01 ...

Page 63: ...ble readers 1 Electrical connection version of the backplane bus For supply voltage S7 1200 backplane bus Screw terminals Version of the interface to the reader 9 pin D sub female Max block length 1 word cyclic 240 bytes acyclic Mechanical specifications Material Xantar MX 1094 Color Ti Grey 24L01 Maximum tightening torque of the screw for securing the equipment 0 45 Nm Electrical data Supply volt...

Page 64: ...ions LED display 4 LEDs for reader connection 1 LED for device status Function blocks SIMATIC S7 1200 and S7 1500 Library with function blocks Read Write Read_EPC ID Write_EPC ID Set_Ant Reset_Reader AdvancedCmd Transponder addressing Direct access via addresses Communications protocol S7 communication Commands Initialize transponder Read data from transponder Write data to transponder etc Standar...

Page 65: ...s module RF120C with application blocks for S7 1200 and S7 1500 Operating Instructions 07 2013 C79000 G8976 C328 01 65 Dimension drawings 7 Figure 7 1 Dimension drawing RF120C communications module dimensions in mm ...

Page 66: ...Dimension drawings Communications module RF120C with application blocks for S7 1200 and S7 1500 66 Operating Instructions 07 2013 C79000 G8976 C328 01 ...

Page 67: ...s and applications Contact your Siemens representative if you would like a list of the current approvals or check the Internet pages of Siemens Automation Customer Support Current approvals http support automation siemens com WW view en 44632196 Go to the relevant product there and select the Certificates entry type from the Entry list tab Approvals for SIMATIC NET products You will find an overvi...

Page 68: ... official gazettes of the European Union EC directive 2006 95 EC Electrical Equipment Designed for Use within Certain Voltage Limits low voltage directive EN 61131 2 2007 Programmable logic controllers equipment requirements and tests EC directive 2004 108 EC Electromagnetic Compatibility Directive EMC directive Emission EN 61000 6 4 A1 2007 2011 Industrial area Immunity EN 61000 6 2 2005 Industri...

Page 69: ...ol Equipment C Tick approval The product meets the requirements of the standards according to AS NZS 61000 6 4 2007 Class A Additional information is available in the Operating Instructions S7 1200 Programmable Controller FCC approval FCC Code of Federal Regulations CFR 47 Part 15 Sections 15 107 and 15 109 Class A Industry Canada Interference Causing Equipment Standard ICES 003 Issue 4 Sections 5...

Page 70: ...ic discharge 8 kV air discharge to all surfaces 4 kV contact discharge to exposed conductive surfaces EN 61000 4 3 Radiated electromagnetic field 80 1 000 MHz 10 V m 80 AM at 1 kHz 1 4 2 0 GHz 3 V m 80 AM at 1 kHz 2 0 2 7 GHz 1 V m 80 AM at 1 kHz EN 61000 4 4 Fast transient bursts 2 kV 5 kHz with coupling network to AC and DC system power 1 kV 5 kHz with coupling clamp to inputs outputs EN 61000 4...

Page 71: ...below device 0 C to 55 C for horizontal installation of the rack 0 C to 45 C for vertical installation of the rack 95 relative humidity non condensing Atmospheric pressure 1080 795 hPa corresponding to an altitude of 1000 to 2 000 m EN 60068 2 14 Test Nb temperature change 5 to 55 3 C minute EN 60068 2 27 Mechanical shock 15 g 11 ms pulse 3 positive and 3 negative shocks in each of the 3 axes half...

Page 72: ...d cables Connecting cable for RF120C Figure A 1 Connecting cable M12 D sub Connecting cable betw RF120C RF200 RF300 RF600 MV400 Length 2 m 5 m 10 m Extension cable Figure A 2 Extension cable M12 M12 Extension cable for all readers Length 2 m 5 m 10 m 20 m 50 m Connecting cable MOBY U Figure A 3 M12 connecting cable reader Can only be used in conjunction with a connecting cable 6GT2091 4Lxxx Length...

Page 73: ... every reader configuration with the maximum cable length of 50 m In some situations longer connecting cables up to 1000 m are possible The current consumption of the connected reader must however be taken into account You will find further information in the relevant system manuals Do not connect more than 2 pieces of cable 3 pieces for MOBY U D together to form a longer cable since this produces...

Page 74: ...12 connector male Reader connector female 1 2 2 5 3 3 4 4 5 6 6 1 7 8 7 Table A 3 Connecting cable extension cable M12 M12 M12 connector male M12 connector female 1 1 2 2 3 3 4 4 5 5 6 6 7 7 8 8 Table A 4 Connecting cable M12 D sub 9 pin M12 connector male Sub D connector female 1 2 5 3 7 4 3 5 2 6 6 7 8 1 8 Note Reader with a D sub connector must be supplied over an additional connector with 24 V...

Page 75: ...ividually assemble their own cables refer to the relevant system manual Cables and reader connectors can be ordered from the catalog ID 10 Industrial Identification Systems Cable structure You will need cables of the following specifications for self assembled cables 7 x 0 25 mm2 LiYC11Y 7 x 0 25 Connectors D sub and M12 connectors can be obtained from specialist dealers e g Binder Pin assignment ...

Page 76: ...4LH50 10 0 m 6GT2091 4LN10 Extension cable for all readers straight connector 2 0 m 6GT2091 4FH20 5 0 m 6GT2091 4FH50 10 0 m 6GT2091 4FN10 20 0 m 6GT2891 4FN20 50 0 m 6GT2891 4FN50 Extension cable for all readers connector angled on reader 2 0 m 6GT2891 4JH20 MOBY D connecting cable only in conjunction with the RF120C connecting cable 2 0 m 6GT2691 4FH20 MOBY U connecting cable only in conjunction...

Page 77: ... 7 SIMATIC manual collection Name Order number Content SIMATIC manual collection 6ES7998 8XC01 8YE0 Contains all SIMATIC manuals in electronic format Table A 8 RFID accessories Name Order number Content DVD RFID Systems Software Documentation 6GT2080 2AA20 FBs FCs for SIMATIC 3964R driver for DOS Windows 95 NT 2000 X P C libraries PC demo program RFID documentation Throughput calculation tool ...

Page 78: ...Appendix A 3 Ordering data Communications module RF120C with application blocks for S7 1200 and S7 1500 78 Operating Instructions 07 2013 C79000 G8976 C328 01 ...

Page 79: ... function blocks have the same function as the Reset_Reader block described earlier However with the blocks described here you need to set reader dependent parameters Remember that the default value will be used automatically if you do not select a value manually Reset_RF200 Figure B 1 Reset_RF200 function block Table B 1 Explanation of the Reset_RF200 function block Parameter Data type Default va...

Page 80: ..._RF300 function block Table B 2 Explanation of the Reset_RF300 function block Parameter Data type Default value Description TAG_CONTROL Bool True Presence check TAG_TYPE Byte 0 Tag type 1 every ISO transponder 0 RF300 transponder RF_POWER Byte 0 Output power only relevant for RF380R RF power from 0 5 W to 5 W in increments of 0 25 W range of values 0x02 0x14 Default value 0 1 25 W ...

Page 81: ...according to EPC Global range of values 0x01 0x09 depending on the reader variant POWER_ANT1 Byte 0 Transmit power for antenna 1 or internal antenna range of values 0x00 0x0F POWER_ANT2 Byte 0 Transmit power for antenna 2 or external antenna range of values 0x00 0x0F UID_HANDLE Bool False Meaning of the UID in the command True Handle ID only the least significant 4 bytes of the UID are evaluated F...

Page 82: ... processed at the same time in the antenna field Range of values 0x01 0x50 ISTM Bool False True activate intelligent single tag mode SCANNING_MODE Bool False True activate scanning mode Reset_MOBY_D Figure B 4 Reset_MOBY_D function block Table B 4 Explanation of the Reset_MOBY function block Parameter Data type Default value Description TAG_CONTROL Bool True Presence check TAG_TYPE Byte 1 Tag type...

Page 83: ...ription TAG_CONTROL Bool True Presence check DISTANCE Byte 23h Range limitation range of values 0x02 0x23 or 0x82 0xA3 for reduced transmit power MULTITAG Byte 1 Maximum number of transponders that can be processed at the same time in the antenna field Range of values 0x01 0x12 SCAN_TIME Byte 0 Scanning time Standby time of the transponder range of values 0x00 0xC8 FCON Byte 0 field_ON_control BER...

Page 84: ...oducts simply call the FB and activate the EXECUTE parameter Figure B 6 Reset_MV function block Table B 6 Explanation of the Reset_MV function block Parameter Data type Description PROGRAM Byte Program selection B 16 0 Reset without without program selection or in the case of diagnostics the error code for IN_OP 0 is fetched B 16 1 B 16 15 Number of the program to be started Reset with program sel...

Page 85: ...function block is a universal reset block with which all systems can be reset Use this FB only after consulting Support Figure B 7 Reset_Univ function block Table B 7 Explanation of the Reset_Univ function block Parameter Data type Description PARAM Array 1 16 of Byte Data for Reset frame The data to be set here can be made available by Support when necessary for special settings ...

Page 86: ...Reset function blocks Communications module RF120C with application blocks for S7 1200 and S7 1500 86 Operating Instructions 07 2013 C79000 G8976 C328 01 ...

Page 87: ...tructure must be specified in the CMD input parameter You need to create the structure for the CMD parameter in a data block or as a data type Figure C 1 AdvancedCmd function block Table C 1 Explanation of the AdvancedCmd function block Parameter Data type Description UID Array 1 8 of Byte Unique Identifier of the transponder CMD Struct CMD_ID Byte ID of the command LEN_DATA INT Length of the data...

Page 88: ...A1h 1 Format 66h Value 15 The memory size and the initialization value must be stored in the data buffer 2 1 Details See Function manual for RF620R RF630R There the DEV status corresponds to the SLG Status command and Inventory corresponds to the GET command The attributes must be compiled as follows 81h 01h 82h 02h 83h 03h 85h 05h 87h 07h 90h 10h 91h 11h 92h 12h A0h 20 A01 21 2 Details refer to t...

Page 89: ...erface of the Ident profile If the functionality available with the function blocks is not adequate for your application you can use the Ident profile as an alternative Using FB 101 you can set complex command structures The following graphic shows the Ident profile including the commands that can be implemented with it Figure C 2 Input parameters for RF120C with FB 101 Ident profile You will find...

Page 90: ...ads data from a transponder by specifying the physical start address and length PHYSICAL WRITE 71 q UID Length StartAddress Writes data to a transponder by specifying the physical start address and length PUT 65 e Length Transfers further commands not specified in the standard profile To this end a corresponding data structure is defined in the send data buffer for each command Put_SET_ANT Switche...

Page 91: ...e following pages On the Internet http www siemens com automation partner In Catalog CA 01 In the catalog ID 10 specially for Industrial Identification Systems Service support for industrial automation and drive technologies You can find various services on the Support homepage http www siemens com automation service support of IA DT on the Internet There you will find the following information fo...

Page 92: ...e on the Internet SIMATIC Guide manuals http www siemens com simatic tech doku portal Online catalog and ordering system The online catalog and the online ordering system can also be found on the Industry Mall Homepage http www siemens com industrymall Training center We offer appropriate courses to get you started Please contact your local training center or the central training center in D 90327...

Reviews: