Parameter assignment and configuration
4.3 Parameter assignment with the device configuration
Communications module RF120C with application blocks for S7-1200 and S7-1500
Operating Instructions, 07/2013, C79000-G8976-C328-01
23
Submenu: Diagnostics
Parameter assignment options:
●
None
Apart from standard diagnostics, no other alarms are generated.
●
Hard errors
Extended alarms are generated if the following events occur.
–
Hardware fault (memory test)
–
Firmware error (checksum)
–
Connection to reader lost
–
Short-circuit fault/interruption if supported by the hardware
You will find more detailed information on diagnostics in the section "Diagnostics (Page 49)".
4.3.2
Menu: Reader System
Menu: Reader System
In this menu you can set all specific parameters for the selected RFID system.
Figure 4-3
General parameter assignment options of the RF300 reader system