Hardware Information
Release 04/02
7-21
Panel PC 670 Computing Unit, Equipment Manual
Display port (LVDS), X400
TFT displays with an LVDS port can be connected to this port. 18-bit displays
having a resolution up to 1024x768 pixels can be connected. The permissible
display clock rate is 20 MHz to 66 MHz. The display is selected automatically
according to the code of the Display Select inputs. The display supply voltages
(3,3 V and 5 V) are connected as a function of the requirements for the connected
displays via the graphics controller. The maximum cable length is 50 cm at a
transfer rate of 455 MHz. Specific cable properties have to be taken into account
for differential cable pairs in accordance with the LVDS specification.
Pin
No.
Short Name
Meaning
Input/Output
1
P5V_D_fused
+5V (fused) Display VCC
Output
2
P5V_D_fused
+5V (fused) Display VCC
Output
3
RXIN0–
LVDS output signal bit 0 (-)
Output
4
RXIN0+
LVDS output signal bit 0 (+)
Output
5
P3V3_D_fused
+3.3V (fused) display VCC
Output
6
P3V3_D_fused
+3.3V (fused) display VCC
Output
7
RXIN1–
LVDS output signal bit 1 (-)
Output
8
RXIN1+
LVDS output signal bit 1 (+)
Output
9
GND
Chassis ground
-
10
GND
Chassis ground
-
11
RXIN2–
LVDS output signal bit 2 (-)
Output
12
RXIN2+
LVDS output signal bit 2 (+)
Output
13
GND
Chassis ground
-
14
GND
Chassis ground
-
15
RXCLKIN–
LVDS clock signal (–)
Output
16
LVDS clock signal (+)
Output
17
GND
Chassis ground
-
18
GND
Chassis ground
-
19
Reserved
20
Reserved
Summary of Contents for SIMATIC PC 670
Page 4: ...For your notes ...
Page 12: ...Contents Release 04 02 xii Panel PC 670 Computing Unit Equipment Manual ...
Page 132: ...Fault Diagnosis Release 04 02 6 12 Panel PC 670 Computing Unit Equipment Manual ...
Page 176: ...Distributed configuration Release 04 02 8 6 Panel PC 670 Computing Unit Equipment Manual ...
Page 194: ...Glossary Release 04 02 Glossary 6 Panel PC 670 Computing Unit Equipment Manual ...
Page 200: ...Index Release 04 02 Index 6 Panel PC 670 Computing Unit Equipment Manual ...