Hardware Information
Release 04/02
7-7
Panel PC 670 Computing Unit, Equipment Manual
7.4.3
Temperature monitoring/display
Temperature monitoring
The temperature is measured by means of three temperature sensors. One sensor
monitors the processor temperature, the second the temperature in the area of the
memory module and the expansion cards and the third the temperature in the area
of the power supply unit.
S
If the temperature near the power supply exceeds 45
o
C (fixed value), the fan is
set to maximum rpms. To activate this feature, the setting “Fan Control” has to
be turned on in the Setup menu (Sec. 6.1.4).
S
If the temperature exceeds one of the three temperature values of the set
thresholds, a temperature error is registered with the following effects:
Reaction
Options
Temp LED from GREEN to RED
Always
Fan goes to maximum rpms.
Always
Trigger IRQ
Adjustable
Temperature errors do not occur during the normal approved use of the device. If a
temperature error occurs, check the following possible causes:
S
Are the ventilation slots blocked?
S
Is the fan working?
S
Is the ambient temperature higher than the allowed value?
S
Has the total capacity for the power supply been exceeded?
The temperature error remains saved until the temperature thresholds are again
exceeded and are reset by one of the following measures:
S
Acknowledge the error message via the SOM program
S
Restarting the device.
Summary of Contents for SIMATIC PC 670
Page 4: ...For your notes ...
Page 12: ...Contents Release 04 02 xii Panel PC 670 Computing Unit Equipment Manual ...
Page 132: ...Fault Diagnosis Release 04 02 6 12 Panel PC 670 Computing Unit Equipment Manual ...
Page 176: ...Distributed configuration Release 04 02 8 6 Panel PC 670 Computing Unit Equipment Manual ...
Page 194: ...Glossary Release 04 02 Glossary 6 Panel PC 670 Computing Unit Equipment Manual ...
Page 200: ...Index Release 04 02 Index 6 Panel PC 670 Computing Unit Equipment Manual ...