Configuring with Web Based Management
5.2 Login
SCALANCE W780/W740 to IEEE 802.11n Web Based Management
62
Configuration Manual, 03/2015, C79000-G8976-C267-08
Logon with HTTP
There are two ways in which you can log on via HTTP. You either use the logon option in the
center of the browser window or the logon option in the upper left area of the browser
window.
The following steps apply when logging on, whichever of the above options you choose:
1.
Enter the following in the "Name" input box:
–
"admin": With this user type, you can change the settings of the device (read and write
access to the configuration data).
–
"user": With this user type, you cannot change any of the settings of the device (read
access to the configuration data).
2.
Enter your password in the "Password" input box.
When you log on for the first time or following a "Restore Factory Defaults and Restart",
enter the standard password in the "Password" input box.
–
"admin": standard password "admin"
–
"user": standard password "user"
3.
Click the "Login" button or confirm your entry with "Enter".
When you log on for the first time or following a "Restore Factory Defaults and Restart",
you will be prompted to change the password. The new password must be at least 6
characters long. You need to repeat the password as confirmation. The password entries
must match. Click the "Set Values" to complete the action and activate the new
password.
Once you have logged in successfully, the start page appears.