Configuring with Web Based Management
5.5 "System" menu
SCALANCE W780/W740 to IEEE 802.11n Web Based Management
Configuration Manual, 03/2015, C79000-G8976-C267-08
177
Description
The page contains the following boxes:
●
Group Name
Enter the name of the group. The maximum length is 32 characters.
●
Security Level
Select the security level (authentication, encryption) valid for
the selected group. In the security levels, the following options:
–
No Auth/no Priv
No authentication enabled, no encryption enabled.
–
Auth/no Priv
Authentication enabled / no encryption enabled.
–
Auth/Priv
Authentication enabled / encryption enabled.
The table has the following columns:
●
Select
Select the row you want to delete.
●
Group Name
Shows the defined group names.
●
Security Level
Shows the configured security level.
●
Read
Enable or disable read access for the required group.
●
Write
Enable or disable wite access for the required group.
Note
For write access to work, you also need to enable read access.
●
Persistence
Shows whether or not the group is assigned to an SNMPv3 user. If the group is not
assigned to an SNMPv3 user, no automatic saving is triggered and the configured group
disappears again after restarting the device.
–
Yes
The group is assigned to an SNMPV3 user.
–
No
The group is not assigned to an SNMPV3 user.