Configuring with Web Based Management
5.5 "System" menu
SCALANCE W780/W740 to IEEE 802.11n Web Based Management
Configuration Manual, 03/2015, C79000-G8976-C267-08
205
●
Device Type
Shows the device type within the product line that used the C-PLUG or KEY-PLUG
previously.
●
Configuration Revision
The version of the configuration structure. This information relates to the configuration
options supported by the device and has nothing to do with the concrete hardware
configuration. This revision information does not therefore change if you add or remove
additional components (modules or extenders), it can, however, change if you update the
firmware.
●
File System
Displays the type of file system on the PLUG.
NOTICE
New file system UBI
As of SCALANCE W firmware version 2.0, UBI is the standard file system for the C-
PLUG or KEY-PLUG. If a C-PLUG with the previous file system IECP is detected in
such a device, this C-PLUG will be formatted for the UBI file system and the data will be
rewritten to the C-PLUG.
The file system is also changed following a firmware update to V2.0 with SCALANCE W.
A downgrade to the previous version of the corresponding software is then a problem.
The firmware can neither read nor write the C-PLUG or KEY-PLUG and it is not even
possible to "Erase PLUG to Factory Default".
●
File System Size [Byte]
Displays the maximum storage capacity of the file system on the PLUG.
●
File System Usage [Byte]
Displays the memory utilization of the file system of the PLUG.
●
Info String
Shows additional information about the device that used the PLUG previously, for
example, order number, type designation, and the versions of the hardware and software.
The displayed software version corresponds to the version in which the configuration was
last changed. With the "NOT ACCEPTED" status, further information on the cause of the
problem is displayed.
●
"Modify PLUG" drop-down list
Select the setting from the drop-down list. You have the following options for changing
the configuration on the C-PLUG or KEY-PLUG:
–
Write current configuration to PLUG
This option is available only if the status of the PLUG is "NOT ACCEPTED" or
"FACTORY".
The configuration in the internal flash memory of the device is copied to the PLUG.
–
Erase PLUG to factory default
Deletes all the data from the PLUG and runs a low-level formatting function.