2.7 Digital input / output
SCALANCE W780/W740 to IEEE 802.11n Web Based Management
32
Configuration Manual, 03/2015, C79000-G8976-C267-08
Digital input
Using the private MIB variable snMspsDigitalInputLevel, you can read out the status of the
digital input.
Note
If the digital output changes status, an entry is made in the event protocol table.
●
OID of the private MIB variable snMspsDigitalInputLevel:
iso(1).org(3).dod(6).internet(1).private(4).enterprises(1).siemens(4329).industria
lComProducts(20).iComPlatforms(1).simaticNet(1).snMsps(1).snMspsCommon(1).snMspsDi
gitalIO(39).snMspsDigitalIOObjects(1).snMspsDigitalInputTable(2).snMspsDigitalInpu
tEntry(1).snMspsDigitalInputLevel(6)
●
values of the MIB variable
–
1: Signal 0 at the digital input (DI)
–
2: Signal 1 at the digital input (DI)
MIB file
The MIB variables can be found in the file "SN-MSPS-DIGITAL-IO-MIB" that is part of the
private MIB file "snMspsWlan.mib". You will find more detailed information in "Private MIB
variables of the SCALANCE W700 (Page 305)".