Configuring with Web Based Management
5.5 "System" menu
SCALANCE W780/W740 to IEEE 802.11n Web Based Management
200
Configuration Manual, 03/2015, C79000-G8976-C267-08
5.5.15.2
Link Change
Configuration of fault monitoring of status changes on connections
On this page, you configure whether or not an error message is triggered if there is a status
change on a network connection.
If connection monitoring is enabled, an error is signaled
●
when there should be a link on a port and this is missing.
●
or when there should not be a link on a port and a link is detected.
A fault causes the signaling contact to trigger and the fault LED on the device to light up and,
depending on the configuration, can trigger a trap, an e-mail, or an entry in the event log
table.
Description
The table has the following columns:
●
Port
Shows the available ports.
●
Setting
Select the setting from the drop-down list. You have the following options:
–
Up
Error handling is triggered when the port changes to the active status.
(From "Link down" to "Link up")
–
Down
Error handling is triggered when the port changes to the inactive status.
(From "Link up" to "Link down")
–
"-" (disabled)
The error handling is not triggered.
Procedure
1.
From the relevant drop-down list, select the options of the slots / ports whose connection
status you want to monitor.
2.
Click the "Set Values" button.