Application
5.1 Program
SIMATIC MV500
Operating Manual, 05/2019, C79000-G8976-C495-02
23
5.1.1.2
Program sequence
Table 5- 5
Program sequence
Menu command or
parameter
Possible values
Default
Description
Programs con-
tained
1 ... x
1
Select the programs that the program sequence
should use. You can select the programs with the
left mouse Ctrl.
Use 1st image
On/Off
Off
Turn on this parameter to use an image acquisi-
tion with the acquisition settings of the first pro-
gram sequence contained in the program. Using
the acquired image, processing is attempted with
all the programs selected in the "Programs con-
tained" parameter.
If the parameter is disabled, separate image ac-
quisition is carried out for each program selected
in the "Programs contained" parameter with the
image acquisition settings stored in this program.
5.1.2
"Overview" program step
The program overview provides you with information about the currently selected program
and you are given the option of having the parameters assigned automatically or making the
settings manually.