Settings
6.2 Options
SIMATIC MV500
124
Operating Manual, 05/2019, C79000-G8976-C495-02
Time basis
In this group, you specify the source for the time stamp of the diagnostics events.
Table 6- 19 Time basis
Parameter
Possible values
Default
Description
Source
PC
SNTP
PC
•
PC: The PC provides the time stamp.
•
SNTP: An SNTP server (SNTP = simple network
time protocol) in the network provides the time
stamp.
IP address
xxx.xxx.xxx.xxx
192.168.0.44
IP address of the SNTP server (enabled only when
Source = SNTP)
Monitoring
In this group, you specify whether live images are displayed in processing mode.
Table 6- 20 Monitoring
Parameter
Possible values
Default
Description
During processing
•
Auto
•
Off
•
On
Auto
Here, you specify whether a live image is displayed
in processing mode on the "Run" page:
•
Off: No live image
•
On: Live image is displayed
•
Auto: Live image is displayed load-dependent
Persistence (persistent data storage)
In this group, you specify which diagnostic information you want to store permanently on the
EPROM.
Table 6- 21 Persistence
Parameter/
button
Possible values
Default
Description
Save next error image
☐
/ ☑
☐
The image belonging to the next NOK signal is
saved in the EPROM. If an image is already stored
there, it is overwritten when this function is selected.
Save next data rec-
ords
☐
/ ☑
☐
As soon as the function is enabled, as many diag-
nostics entries as you specify in the following input
box are saved in the EPROM. Existing entries are
deleted when you switch over to On. If the diagnos-
tics buffer in the EPROM reaches the number of
permanently storable diagnostic data records, no
further entries are made.
Note