Installing and connecting the device
3.3 Mounting the device
IFP2200 INOX MT ETH
Compact Operating Instructions, 03/2018, A5E42185570-AA
19
2.
Carefully place the device on the front panel (interfaces pointing to you), and insert the
mounting seal into the stainless steel front panel as shown. Also pay attention to numbers
④
-
⑥
.
④
Seal corner is underneath the housing frame.
⑤
The coding tap is flush on the provided cutout.
⑥
Positioning hook of the seal engages completely in cutout, flush and without overhang.
Similar to figure
3.
Check the correct fit of the mounting seal:
–
The coding tap is placed at the specified location.
–
All positioning hooks rest flush in their cutouts. The mounting seal is installed correctly
when it lies flat on the entire stainless steel front. There must be no distortions or
overhangs as shown in the picture detail.
If necessary, adjust the seat: To do this, press the mounting seal into the cutout at the
marked points.
–
The edge of the mounting seal is flush with the edge of the stainless steel front all
around.
3.3
Mounting the device
Requirement
●
All packaging components and the edge protection tape, if present, have been removed.
●
1 clamping frame
●
1 torque wrench for 1.3 Nm with 2.5 mm with hex socket insert.
●
Fasteners: 30 mounting clips
Siemens Drives & PLCs