Technical specifications
5.5 Ambient conditions
IFP2200 INOX MT ETH
36
Compact Operating Instructions, 03/2018, A5E42185570-AA
DC power supply
IFP2200 MT ETH
Rated voltage
24 V DC, electrically isolated *
Power consumption
1
40 W
* Electrical isolation within the safety extra-low voltage circuit
1
The power loss generally corresponds to the specified value for power consumption.
Material
Component
Material
Front frame
Stainless steel, material number 1.4301, V2A
Front glass
Float glass, toughened; tempered safety glass (ESG)
•
Shock-resistant according to EN62262 IK08 (5J, ball drop test)
•
Anti-glare (gloss 85) through etching
•
No surface coating
•
Injury-avoidance (occupational safety): Defined fracture pattern when
broken: Breaks into glass particles (no sharp-edged splinters)
Mounting gasket
EPDM, 70 Shore A, black
5.5
Ambient conditions
5.5.1
Transport and storage conditions
Proper transport and storage, installation and assembly as well as careful operation and
maintenance are prerequisites for trouble-free and safe operation of the device.
Non-compliance with these regulations shall render the device warranty void.
Mechanical transport and storage conditions
The following information is for a device that is transported and stored in its original
packaging.
The device meets the requirements according to IEC 60721-3-2 Class 2M2 with the following
amendments and limitations:
Type of condition
Permitted range
Free fall
≤
1 m
Vibration according to IEC 60068-2-6
5 .. 8.4 Hz, deflection 3.5 mm
8.4 ... 500 Hz, acceleration 1 g
Shock according to IEC 60068-2-27
250 m/s
2
, 6 ms, 1000 shocks