"SIMATIC Mobile Reader" app
5.2 Functions of the HF app variant (RF360M)
Mobile reader SIMATIC RF360M/RF660M
Operating Instructions, 08/2022, C79000-G8976-C660-02
39
Table 5- 4
Functions of the "Memory editor" tab
Functions/
parameter
Description
Memory area
Drop-down list to select the memory area within which you want to change or
write the data of the target transponder.
The memory areas that can be selected depend on the transponder protocol with
which the transponder located in the antenna field works.
The following memory areas are possible:
•
USER_FRAM
•
USER_EEPROM
•
OTP_EEPROM
Format
Drop-down list to select the input format of the data to be written.
•
HEX
Hexadecimal input format. Hyphens are entered automatically.
•
BIN
Decimal input format. Numbers 0 and 1 are allowed.
•
DEC
Decimal input format. Numbers from 0 ... 255 are allowed.
•
ASCII6
ASCII6 input format. All characters compliant with VDA 5500 are allowed.
•
ASCII8
ASCII8 input format. All ASCII characters are allowed.
Address
Input box for entering the address within the selected memory area from which
you want to read, change or write the data of the target transponder.
The address can be specified in decimal or hexadecimal (0x...) input format.
Length
Input box for entering the length within the selected memory area in which you
want to read, change or write the data of the target transponder.
The length can be specified in decimal or hexadecimal (0x...) input format.
Read
Button to execute the read operation
Write