3.1.5 Timer screen
Fig 3-16
Timer screen 1
Operating sequences
Press this key to enter the timer screen 1. See Fig 3-16 Timer
screen 1.
On this screen, the working time for every action and the delay time for
action switch, as well as protection time for charging can be set.
Cycle time (TmCyc)
-
It is the time to monitor one machine cycle. If the
actual machine cycle time is longer than the set value, then there is
alarm.
Interval time (Interval)
-
When one cycle is finished, there is an
interval time before the next machine cycle start. This setting is only
applicable in time auto mode.
Cooling time (TcCool)
-
When injection is finished, the timer begins to
work. This interval is to make sure that the material has enough time for
cooling.
Charging delay (TdCha)
-
It is the interval time between injection and
charging, which is to prevent the overheating of plastic material.
Injection delay (TdInj)
-
When the carriage arrives at the injection
position, it will wait certain time before injection.
Core in delay (TdCorIn)
-
When previous work is finished, core in will
begin after a delay time.
Core out delay (TdCorOut)
-
When previous work is finished, core out
will begin after a delay time.
Ejector advance delay (TdEjeAdv)
-
When mold open is ended,
ejector advance will begin after a delay time.
Ejector retract delay (TdEjeRet)
-
When ejector advance is finished,
ejector retract will begin after a delay time.
Mold close time (TmMldClo)
-
The total time for mold close, which is
monitoring time. There is event message if the setting time is exceeded.