Operator panel keys
SIJECT 15/16 Operation Manual June, 2003
2-8
2.4
Manual Operating Keys
General
All the manual keys
and
described below can function only after
the Manual mode and Mold adjustment is running.
Mold key
Press the middle Mold key to enter
Mold screen
.
Input corresponding parameter (Position, pressure, flow and protecting
time) for each step.
Mold will open continuously if you keep pressing the left key.
Mold will close continuously if you keep pressing the right key.
Mold close/open keys can be operated in combination with core in/out
keys, for example, “Core in” can be done during, before or after mold
close, or “Core out” during, before or after mold open.
Ejector key
Press the middle Ejector key to enter
Ejector screen
.
Now you can input corresponding parameter (Position, pressure, flow
and counter) for ejector advance and retract, and set counter and
ejector mode.
Ejector will retract continuously if you keep pressing the left key.
Ejector will advance continuously if you keep pressing the right key.
Repeat above-mentioned two steps to carry out multiple ejection.
Carriage key
Press the middle Carriage key to enter
Carriage screen
.
Now you can input corresponding parameter (pressure, flow and
injection time) for carriage advance and retract.
Carriage will advance continuously if you keep pressing the left key.
Carriage will retract continuously if you keep pressing the right key.