Description
3.5 Design of the charging station
SICHARGE D
Operating Instructions, 02/2021, 8EM5907-0AA00-1AA7.01
33
In the lower area, the ground cables are connected to the busbars of the charging station (cf.
Section Mains connection (Page 66)). From here, the supply of the power lines and the
automation as well as other consumers takes place. The protective elements for the internal
devices and the fuses for the supplies of the dispensers are also located here.
The AC/DC converters are in the center area of the charging station behind a cover. Among
other things, they guarantee galvanic isolation between the mains and the vehicle.
The automation devices are located above the converter cover.
On the back of the door, the AC power line is at the bottom, the devices for consumption
measurement at the side, and the routers for wireless connection to the backend system at
the top behind a cover. More information on the devices is provided in the section Routers
(Page 37). The following figure shows the rear view of the door.
Figure 3-8
Position of the router