Configuration
4.2 Procedure for configuration
Fail-safe operation of the Mobile Panel 277F IWLAN
54
Function Manual, 08/2008, 6AV6691-1FQ01-2AB0
Basic procedure
Always use the following procedure for configuration:
1.
Create a STEP 7 project in the SIMATIC Manager.
2.
Configure the required F-CPU and a PROFINET connection in the hardware
configuration "HW Config".
3.
Insert a Mobile Panel 277F IWLAN in the configuration from the hardware catalog of the
HW Config by dragging it to the PROFINET connection in the station window via
Drag&Drop.
4.
Call the object properties of the Mobile Panel 277F IWLAN using the context menu (right
mouse button) and configure the communication between the HMI device and the PLC,
see Assigning parameters for communication between the HMI device and the controller
5.
Configure other components in accordance with your plant.
6.
Create a safety program for the F-CPU in STEP 7 with S7 Distributed Safety. Insert the
F-FBs required for the HMI device in the safety program and wire them according to
instructions. Do this according to the checklist Checklist: Creation of the safety program
7.
Start WinCC flexible ES and create a project for the HMI using the Wizard.
8.
Set "Ethernet/Wireless" in the project view under "Communication".
9.
Set the PROFIsafe address of the HMI device in the project view under "Device settings"
> "Device settings".
10.
Configure the effective ranges planned for your plant under "Device settings" > "Effective
ranges", see Effective ranges editor (Page 73).
11.
Configure the figures for operating and monitoring the plant. Insert the objects required
for working with effective ranges in these figures, see Objects for the Mobile Panel 277F
Further information
You have central access to SIMATIC documentation under SIMATIC in the Start menu on
the configuration computer.
More detailed information can be found under the following references:
Tool
Task
Documentation
STEP 7, HW Config
Creation of the project for the
automation system
SIMATIC > Documentation >
desired language
S7 Distributed Safety
Creation of the safety program
SIMATIC > Documentation >
desired language
WinCC flexible
Creation of the project for the
HMI device
SIMATIC > WinCC flexible 2007
> WinCC flexible help system