Appendix B
B.1 MIB variables of a SCALANCE X300/X400
SCALANCE X-300 / X-400
368
Configuration Manual, 10/2014, C79000-G8976-C187-22
Variables
Access rights
Description
sysLocation
Read and write
Here, the location of the device can be entered (de-
fault: empty string).
Possible value: string with a maximum of 255 charac-
ters.
sysService
Read only
Shows the functions (services) provided by the com-
ponent according to the ISO/OSI model.
Level functionality:
•
Physical (for example repeater)
•
Datalink/subnet (for example bridges, switches)
•
Internet (for example IP gateways, routers)
•
End to end (for example IP hosts)
•
Applications (for example E-mail servers)
Data type: 32-bit integer.
Variables in the Interface directory
Table B- 2
Variables in the Interface directory
Variables
Access rights
Description
ifNumber
Read only
The number of different interfaces available in the
component.
With a SCALANCE X414-3E, the value 68 is out-
put for this variable (26 physical ports, 42 internal
(virtual) ports.
With a SCALANCE X408-2, the value 17 is output
for this variable (8 physical ports, 9 internal (virtu-
al) ports.
With a SCALANCE X-300, the value 21 is output
for this variable (10 physical ports, 11 internal
(virtual) ports.
Data type: 32-bit integer
ifDescr
Read only
A description of and possibly other information on
a port.
Possible value: string with a maximum of 255
characters.
ifType
Read only
With IE switches, the value ethernet-csmacd(6),
gigabitEthernet(117) or fastEther(62) is entered.
Data type: Integer
ifSpeed
Read only
Data transfer rate of the Ethernet port in bits per
second. With IE switches either 10 Mbps, 100
Mbps, or 1000 Mbps is displayed.
Data type: Gauge.