Error messages
9.3 Error messages of the RF182C
RF182C communication module
74
Operating Instructions, 10/2010
Error code
ASCII hex
Flashing of
ERR LED
1)
Description
000E
14x
ECC error (only possible when ECC_mode = TRUE)
The data could not be read by the MDS.
•
Data of the MDS have been lost (MDS defective).
•
The MDS was not initialized with ECC driver.
– Initialize MDS
•
MDS with EEPROM has reached the end of its service life. The data have been lost.
– Replace the MDS
•
→ The MDS was moved out of the transmission window while being write-accessed
– The MDS is not positioned correctly
•
→ Command to the communication module was issued incorrectly by user
000F
1x
Run-up message from a reader that is connected to the communication module
•
Carry out a RESET
0011
–
Short circuit or overload of the 24 V outputs (error code, presence)
•
The affected output is turned off.
•
All outputs are turned off when total overload occurs
•
A reset can only be performed by turning the 24 V voltage off and on again.
•
Then start RESET
0012
18x
Internal communication module communication error.
•
Connector contact problem on the communication module
•
Defective communication module hardware
– Return communication module for repair
•
Start RESET after error correction
0013
19x
The communication module/SLG U does not have enough buffer storage to store the
command intermediately.
0014
20x
Internal communication module/SLG error.
•
Program execution error on the communication module
•
Turn power of communication module off and on again.
•
Start RESET after error correction
•
MOBY U: Watchdog error on write/read device
0015
21x
Wrong parameterization of the communication module/SLG
•
Check the parameterization
•
RESET command is parameterized incorrectly
•
After a start-up, the communication module has still not received a RESET
0016
22x
•
The communication module is unable to process the command.
•
Client command (e.g. READ) issued with too much user data
0017
23x
Communication error
•
Check the client command which causes this error
•
Start RESET after error correction
0018
–
An error has occurred which must be acknowledged with a RESET.
•
The RESET command is faulty.
•
Transmit RESET after error correction