Technical data
RF182C communication module
102
Operating Instructions, 10/2010
Ambient temperature
During operation
0 to +60 °C
Transport and storage
–40 to +70 °C
Dimensions (W x H x D) in mm
Base unit only
60 x 210 x 30
Base unit with connection block M12,
7/8''
60 x 210 x 54
Base unit with push-pull connection
block
60 x 216 x 100
Weight
Base unit
Approx. 210 g
Connection block M12, 7/8''
Approx. 230 g
Push-pull connection block
Approx. 120 g
Mechanical Environmental Conditions
Mounting position
All mounting positions are possible
Vibration during operation
According to IEC 61131-2:
0.75 mm (10Hz to 58 Hz)
10 g (58 Hz to 150 Hz)
Shock resistance, shock during
operation
Acc. to IEC 61131-2:
30 g
Degree of protection
IP67
MTBF (Mean Time Between Failures) in years
Base unit
121
Connection block
1100
Approvals
cULus (file E116536)
FCC Code of Federal Regulations,
CFR 47, Part 15,
Sections 15.107 and 15.109 (Class A)
1)
All supply and signal voltages must be safety extra low voltage (SELV/PELV according to
EN 60950)
24 V DC supply: Safety (electrical) isolation of low voltage (SELV / PELV acc. to EN 60950)
2)
The power supply must provide the current required (max. 500 mA) during brief power failures of ≤
20 ms.
3)
A cable cross-section of 2.5 mm² is mandatory for an amperage > 8 A.