Command and acknowledgement telegrams
RF182C communication module
116
Operating Instructions, 10/2010
GetReaderStatus mode = 07
6/*VWDWXV
5HVXOWPHVVDJHIUDPH
PRGH
7KHPHDQLQJRIWKH6/*VWDWXV
LVGHVFULEHGLQWKHIROORZLQJWDEOH
Byte
0
1
2
3 4 5 6
7 8 9 10
11
12 13
14
15
16
17
Param S-Info HW
HW-V
res0
FW
FW-V TR
H Min. Sec res1 SLG-V Baud
Byte
18
19
20
21
22
23
24
25
26
Param res2
dili_
SLG
multi field_on_
control
field_on_
time
expert ant
scanning
_time
MDS
control
Parameter name
Comment
S-Info
Reader status mode information = 07
HW
Hardware type
HW-V
Hardware version
res0
Reserved
FW
Firmware type
FW-V
Firmware version
TR
Driver type
H
hours
Min.
Minutes
Sec
Seconds
res1
Reserved
SLG-V
Reader version
Baud
Baud rate
res2
Reserved
dili_SLG
Set transmission performance
multi
Multitag reader
field_on_control
Set communication type
field_on_time
Set channel
expert
Expert mode
ant
Status of antenna
scanning_time
Radio communication profile
MDS control
Presence mode
For detailed information, please refer to the respective reader description.