Communication interface
6.2 Configuration parameters of the RF182C
RF182C communication module
Operating Instructions, 10/2010
51
Parameter
Parameter
Data type
Values
Version
ASCII
0 ... 9, A ... Z
Here you must enter the following version of the protocol as string:
•
V1.0
RF182C
ASCII
Here you must enter the following values:
•
RF182C
Baud rate
ASCII
Here you must enter one of the following baud rates (in baud):
•
19200
•
57600
•
115200
LEDSuppression
ASCII
Both channels, or channel 1 or channel 2 are flashing
•
NONE = run-up flashing is not suppressed by any of the two reader
terminals
•
TRANSM_POINT_1 = run-up flashing of the err_LED at the reader 1
terminal is being suppressed
•
TRANSM_POINT_2 = run-up flashing of the err_LED at the reader 2
terminal is being suppressed
Mode
ASCII
U/D/RF300_DIRECT_ADDRESSING
Note
The baud rate and mode cannot be set individually; they apply for both channels.