Attach the red hose of the hose set to the con-
■
nection valve (6c) (see figure d).
d
Open the main tap of the house water supply.
■
Open the connection valve (6c) again and check
■
the connection for leaks.
Water pressure:
A minimum of 0.14 MPa (1.4 bar)
A maximum of 0.83 MPa (8.3 bar)
If the pressure is under 0.14 MPa (1.4 bar), a
■
pressure booster pump is to be built in.
If the pressure is over 0.83 MPa (8.3 bar), a pres-
■
sure reducer is to be built in.
Water temperature
Cold water line temperature: 5 – 35 °C
Info
If the water supply is very dirty, it is recommended
that a pre-filter* be installed. This part is available
under order number BZ00PF1.
* not WQA (Water Quality Association) certified
Electrical connection
Only plug the appliance plug into a separate
■
electrical socket.
The socket must be located in the vicinity of the
Water Purifier and be freely accessible.
Modifications to the connection must be made
■
by a specialist.
Operating temperature
Permissible room temperature: + 10 to 43 °C
Ventilation
Never cover the ventilation and breather openings.
Otherwise, the cooling system must work harder
and more electrical power will be consumed.
Start up
Important
The appliance must be connected to the water sup-
ply line and to the waste water line.
The appliance must remain inoperative for
at least
30 minutes
before connecting to the electric circuit
and starting up (to avoid damage to the cooling
system).
Before using the appliance, please fill and com-
■
pletely empty out the filtered water two-times
from the water tanks.
To do this, proceed as follows:
Activating the filters
Insert the plug into a separate electrical socket.
■
Switch the On/Off switch (14) to
■
I
. All LEDs brief-
ly light up, then just the selected LEDs remain lit.
LED Hot water
LED Cold water