28
en
Declaration of conformity
The filter system is tested in accordance with
Standard NSF/ANSI 58 for reduction of pentavalent
arsenic, barium, cadmium, mercury, selenium, ra-
dium 226/228, trivalent and hexavalent chromium
and lead as well as nitrates/nitrites. The results
have been confirmed by laboratory tests. The water
purifier is tested in accordance with Standard NSF/
ANSI 42, 53 for reduction of chlorine and volatile
Installation
Safety information
Risk of electric shock!
The statutory regulations of the respective coun-
–
try, as well as those of the local electricity and
water suppliers must be adhered to.
Only install the appliance in accordance with the
–
local rules and regulations.
First connect to the water connection and drain,
–
then connect the electrical power supply.
The Water Purifier must be disconnected from
–
the mains power network during installation.
Make sure that the house‘s electrical earth/
–
grounding system is installed in accordance with
the regulations.
Do not use extension cables.
–
Only plug into a separate electrical socket. Do
–
not share electrical outlet with other devices.
The Water Purifier has only to be installed in a
–
frost-free room.
Protect plastic parts and cables from high
–
temperatures.
Only connect to a cold tap water line.
–
Only connect to a water supply that meets
–
the regulatory requirements of the respective
country.
Only erect in hygienically clean areas.
–
organic compounds, including laboratory testing
which has confirmed the results. This appliance is
approved for the treatment of supply water concen-
trations of up to a maximum of 27 mg/l nitrates and
3 mg/l nitrites (combined) and is approved for water
pressure of 0.14 MPa – 0.83 MPa.
Do not subject the appliance to shaking, vibra-
–
tions or jolts.
Do not erect in the vicinity of a heating source,
–
or place in direct sunlight, or install in rooms
that are very moist.
Erect the appliance away from flammable gases
–
or combustible materials.
Make sure that there is sufficient air circula-
–
tion. Do not erect in closed cabinets, closets or
lockers.
A minimum distance of 10 cm must be main-
–
tained between the appliance and any wall/ob-
ject. Maintain free space around the filter cover
to allow for filter changes.
Only set the Water Purifier on a level, flat surface
–
that is designed to support such a weight.
The electrical plug must be freely accessible after
–
erection of the appliance.
Unpack the appliance and check for transport-
–
related damage.
Please dispose of the packaging, and if appli-
–
cable, the old appliance in an environmentally-
friendly manner.
Summary of Contents for DW03500 pureFlow
Page 25: ...23 de ...
Page 47: ...45 en ...
Page 89: ...87 fr ...
Page 111: ...109 it ...
Page 133: ...131 nl ...
Page 177: ...175 tr ...
Page 200: ...198 ...
Page 201: ......