31
en
Important
The total length of the entire hose set is limited to a
maximum of 5 m. The waste water connection must
be located below the appliance level. The height
difference to the connection at the appliance must
not exceed a maximum of 25 cm. Make sure that
the hose set (11) is not bent or pinched. The flow of
water must not be impeded.
Always use a new hose when replacing the Water
Purifier. Do not reuse the current hose.
max. 25cm
Waste water connection (DW03500 only)
Use the enclosed parts to connect the waste
■
water hose blue (11b) to the drain connection of
the siphon. If needed, install the siphon with a
drain connection.
Water connection
Close the main tap of the house water supply.
■
Connect the connection valve (6c) to the cold
■
water line of the house water supply (see fig-
ures a and b).
a
b
6c
6a
6a
Important
Do not under any circumstances connect to the
warm water supply.
DW03500 only
: If needed, use the enclosed adapter
(6a) (see figure b).
Close the connection valve (6c) (see figure c).
■
c
6c