Technical specifications
6.1 Technical specifications
Analog input module AI 4xRTD/TC 4xM12 (6ES7144-5KD50-0BA0)
44
Equipment Manual, 08/2020, A5E48753535-AA
Article number
6ES7144-5KD50-0BA0
Interference voltage suppression for f = n x (f1
+/- 0.5 %), f1 = interference frequency
•
Series mode interference (peak value of
interference < rated value of input range),
min.
40 dB
Interrupts/diagnostics/status information
Alarms
•
Diagnostic alarm
Yes; Parameterizable
•
Limit value alarm
Yes; Parameterizable
Diagnostic messages
•
Wire-break
Yes; Not for ±80 mV
•
Overflow/underflow
Yes
Diagnostics indication LED
•
Channel status display
Yes; green LED
•
for module diagnostics
Yes; green/red LED
Potential separation
between the load voltages
Yes
Potential separation channels
•
between the channels
No
•
between the channels and backplane bus
Yes
•
between the channels and the power sup-
ply of the electronics
No
Isolation
Isolation tested with
707 V DC (type test)
Degree and class of protection
IP degree of protection
IP65/67
Standards, approvals, certificates
Suitable for applications according to AMS
2750
Yes; Declaration of Conformity, see online support
entry 109757262
Suitable for applications according to CQI-9
Yes; Based on AMS 2750 E
Ambient conditions
Ambient temperature during operation
•
min.
-30 °C
•
max.
55 °C
Connection method
Design of electrical connection for the inputs
and outputs
M12, 5-pole
Design of electrical connection for supply volt-
age
M8, 4-pole
ET-Connection
•
ET-Connection
M8, 4-pin, shielded