16
8015383/ZUQ7/V1-3/2020-06 | SICK
O P E R A T I N G I N S T R U C T I O N S | TRANSIC151LP
Subject to change without notice
2
PRODUCT DESCRIPTION
CAUTION:
Observe marking for special operating conditions
Special operating conditions: Marking
“X” on the TRANSIC151LP type plate means the
wall thickness of the temperature probe is 0.2<d<1 mm. In order to maintain the zone
separation, the temperature probe may not be exposed to corrosive atmospheres that
can endanger zone separation.
▸
Check the condition of the temperature probe (e.g., for corrosion) during every
regular maintenance.
CAUTION:
Observe marking for special operating conditions
Special operating conditions: Marking
“X” on the TSA151 type plate means a PELV
power supply unit is mandatory for voltage supply to the TSA151.
▸
“Special local conditions”, page 10
.
▸
TSA151 Power Supply: Protective Extra Low Voltage (PELV) power supply is required.
The 24V inlet of the TSA151 is specified with a fault voltage of Um=60V.