O P E R A T I N G I N S T R U C T I O N S | T - E A S I C
®
8023072/1E22/2022-02-23 | SICK AG
Subject to change without notice
2 0
5
MOUNTING
5.7
Mounting in a T-piece
Use only original T-pieces from SICK. These are available as accessories (see
).
When mounting in these T-pieces, use the sensor variants with a permanently pre-
mounted clamping ring (see
position 4).
During installation, insert the sensor with pre-assembled clamping ring into the T-piece
until the clamping ring is seated in the nozzle. Align the sensor so that the arrow on
the bottom shell of the sensor points in the direction of flow. Hold the T-piece in place
while tightening the coupling nut until there is noticeable resistance. Slightly tighten the
coupling nut at this point using an open-end wrench with a width across flats of 16.
1
Fig. 12: Mounting the T-Easic
®
with permanently pre-mounted clamping ring in a T-piece
NOTE
Removal of the sensor with pre-assembled clamping ring from the T-piece is carried out
in the same way as described in
“5.6 Removing the process connection adapter”
.