â
Example of alternative connection module.
Alternative connection module for Lector621 = V2D621x-xxxxxYx (Y = B or C):
CDM420-0006.
CDM420-0006: an adapter cable (female connector, M12, 17-pin, A-coded/male connec‐
tor, D-Sub-HD, 15-pin) is required to connect the Lector621 = V2D621x-xxxxxYx (Y = B or
C)
NOTE
Activate the CAN data interface in the device with a configuration tool, e.g. the configu‐
ration software SOPAS ET.
Make further settings in the device corresponding to the function of the device in the
system configuration.
13.4.7
Wiring the digital inputs “Sensor 1” and “Sensor 2” of the device in the CDB650-204
Device = Lector621 = V2D621x-xxxxxYx (Y = B or C)
Device
3
CDB650-204
PNP sensor
8
V
S
V
S
V
S
GND
SensGND
3.32 K
6.64 K
Sensor
D
V
in
C
9
9
2
1
C
2
1
12
SGND
6
Shield
11
U
IN
*
A
Out
U
IN
*
GND
S3
Trigger sensor
1
E.g. photo-electric
switch
7
ON
OFF
S3 : SGND-GND
Shield
GND
.
.
.
SensGND
GND
3
1
7
2
6
5
4
8
13
14
17
15
9
10
12
16
11
3
1
7
2
6
5
4
8
13
14
17
15
9
10
12
16
11
6
5
Cable
2
SENS/IN
B
4
9
Figure 42: Trigger sensor supplied with power by connection module CDB650-204
1
Trigger sensor, e.g. for read cycle generation
2
Connection cable 1:1 (female connector, M12, 17-pin, A-coded/male connector, M12, 17-pin, A-coded)
3
Device
4
Input voltage V
in
5
Device: male connector, M12, 17-pin, A-coded
6
Connection module: female connector, M12, 17-pin, A-coded
7
e.g. photoelectric sensor
8
PNP sensor
9
Supply voltage V
S
13
ANNEX
82
O P E R A T I N G I N S T R U C T I O N S | Lector621
8022502/15NT/2020-02-11 | SICK
Subject to change without notice