NOTE
Activate the CAN data interface in the device with a configuration tool, e.g. the configu‐
ration software SOPAS ET.
Make further settings in the device corresponding to the function of the device in the
system configuration.
13.7.7
Wiring the digital inputs “Sensor 1” and “Sensor 2” of the device in the CDM420-0001
Device = Lector621 ECO = V2D621x-xxxxxYx (serial variant, Y = D or E)
Device
4
CDM420-0001
PNP sensor
7
V
S
V
S
V
S
GND
SensGND
3.32 K
6.64 K
Sensor
D
V
in
C
15
1
5
Out
+24V*
GND
S6
ON
OFF
S6 : SGND-GND
Shield
GND
.
.
.
A
Sensor
B
37 SGND
6 Shield
39 +24 V*
GND
SensGND
Trigger sensor
1
8
E.g. photo-electric
switch
6
3
5
1
10
15
6
11
5
Cable
2
Figure 79: Trigger sensor supplied with power by connection module CDM420-0001
1
Trigger sensor, e.g. for read cycle generation
2
Connecting cable permanently connected with the device (male connector, D-Sub-HD, 15-pin)
3
Input voltage V
in
4
Device
5
Connection module: female connector, D-Sub-HD, 15-pin
6
e.g. photoelectric sensor
7
PNP sensor
8
Supply voltage V
S
ANNEX
13
8022502/15NT/2020-02-11 | SICK
O P E R A T I N G I N S T R U C T I O N S | Lector621
123