13.4.3
Connecting supply voltage for the device in CDB650-204
Device = Lector621 = V2D621x-xxxxxYx (Y = B or C)
Device
3
CDB650-204
V
S
V
S
2
1
2
1
5
Shield
1
U
IN
2
GND
U
IN
*
GND
S1
F
Shield
Cable
2
GND
.
.
.
.
.
.
.
.
.
ON
OFF
S1 : POWER
V
s
U
IN
*
POWER
GND
3
1
7
2
6
5
4
8
13
14
17
15
9
10
12
16
11
3
1
7
2
6
5
4
8
13
14
17
15
9
10
12
16
11
V
S
-
U
IN
-
F
S 1
-
U
IN
*
5
4
1
Figure 38: Connecting supply voltage for the device in CDB650-204 connection module
1
Supply voltage V
S
2
Connection cable 1:1 (male connector, M12, 17-pin, A-coded / female connector, M12,
17-pin, A-coded)
3
Device
4
Device: male connector, M12, 17-pin, A-coded
5
Connection module: female connector, M12, 17-pin, A-coded
Function of switch S1
Table 31: Switch S1: Power
Switch setting
Function
ON
Supply voltage U
IN
connected to CDB650-204 and device via fuse and
switch S1 as a supply voltage U
IN
*.
Supply voltage U
IN
* can be additionally tapped at terminals 11 and 14.
OFF
CDB650-204 and device disconnected from supply voltage.
Recommended setting for all connection work.
13.4.4
Wiring serial host interface RS-232 of the device in CDB650-204
Device = Lector621 = V2D621x-xxxxxYx (Y = B or C)
13
ANNEX
78
O P E R A T I N G I N S T R U C T I O N S | Lector621
8022502/15NT/2020-02-11 | SICK
Subject to change without notice