Operating Instructions
ISD 230/260/280 IR Data Transmission Systems
Chapter
4
© SICK AG · Auto Ident · Germany · All rights reserved
8 008 207/30-11-2001
18
Installation
Fig.
4-2: ISD unit with three-point bracket no. 5 306 369 (accessory)
The bracket can be mounted either directly with the rear plate (panel) or via the angled
flange on the mounting base using the 4 holes provided. The position of the holes and
dimensions of the three-point bracket are shown in
Fig. 10-1, Page 52
. Two reference
markings allow both brackets to be adjusted vertically and horizontally (x and y direction),
irrespective of the position of the angled flange (can be mounted on the other side of the
unit).
4.2.6
Mounting accessories
The units will be mounted at the transmitter/receiver stations using 3 movable running
nuts. On each longitudinal side there are two of them in a slot (see
Fig. 3-1, Page 13
). The
maximum depth of engagement in the nuts is 10 mm from the surface of the housing. The
location and dimensions of the nuts are shown in
Fig. 9-1, Page 50
.
An unit can be mounted using the SICK brackets:
•
angle bracket no. 2 013 824
•
three-point bracket no. 5 306 369
Three-point bracket
The three-point bracket facilitates mounting and alignment of the units. A separate bracket
is required for each unit (
Fig. 4-2
).
Distance
IR light spot diameter
50 m
approx. 0.7 m
100 m
approx. 1.4 m
150 m
approx. 2.1 m
Table
4-2: Light spot diameter of transmitter