background image

O P E R A T I N G I N S T R U C T I O N S

i10R and i10P

Safety position switch

GB

SICK AG • Industrial Safety Systems

Erwin-Sick-Straße 1

D-79183 Waldkirch • www.sick.com

8010415/TF49/2009-10-21 • GO/XX

Printed in Germany (2009-11) • All rights

reserved

These operating instructions are original

operating instructions.

1

On safety

This chapter deals with your own safety and

the safety of the equipment operators.

Please read this chapter carefully before

working with the i10R or i10P or with ma-

chines protected by the i10R or i10P.

The national/international legislative provi-

sions regulating the use/installation, commis-

sioning and regular technical inspections of

safety position switches apply. These are, in

particular,

the machinery directive 98/37/EC (from

29.12.2009 the machinery directive

2006/42/EC),

the Low Voltage Directive 2006/95/EC,

the Use of Work Equipment Regulations

Directive 89/655 EEC,

the safety provisions as well as

the accident prevention provisions/safety

regulations.

Manufacturers and users of the machines with

which our safety switches are used are respon-

sible for obtaining and observing all applicable

safety rules and regulations.

1.1

Qualified safety personnel

Only qualified safety personnel are authorised

to mount, install and commission the safety

position switch i10R or i10P. Qualified safety

personnel are defined as persons who

have undergone the appropriate technical

training

and

who have been instructed by the responsible

machine operator in the operation of the

machine and the current valid safety guide-

lines

and

who have access to the operating

instructions.

1.2

Applications of the safety
position switch

Safety position switches of type series i10R or

i10P are position switches with forced opening

that are activated by roller levers (R) or roller

tappets (P). They meet the requirements accor-

ding to EN 60947-5-1. In safety switching

circuits they secure mobile protective equipment

in such a way that

the dangerous state of the machine can only be

enabled when the safety guard is closed

a STOP signal is generated when the safety

guard opens while the machine is operating.

For the control system this means that

activation commands leading to dangerous sta-

tes are allowed to become effective only when

the safety guard is in the protective position and

dangerous states must no longer exist when the

safety guard opens.

Before installing safety position switches a risk

assessment should be performed to

EN ISO 13849-1, Safety of machinery – Safety-

Related Parts of Control Systems,

EN 14121-1, Safety of machinery, Principles of

risk assessment.

The correct use includes

compliance with the applicable requirements for

installation and operation, particularly
– EN ISO 13849-1, Safety of machinery –

Safety-Related Parts of Control Systems,

– EN 1088, Interlocking Devices associated with

Guards,

– EN 60204-1, Electrical Equipment of Machi-

nes.

the regular inspection of the protective device by

qualified safety personnel in accordance with

section 4.2.

1.3

Correct use

Safety position switch i10R or i10P must only be

applied as defined in section 1.2 “Applications of

the safety position switch”. The safety position

switch must only be used on the machine where it

has been fitted, installed and by qualified safety

personnel and in compliance with these operating

instructions.
If the device is used for any other purposes or modi-

fied in any way – also during mounting and installa-

tion – any warranty claim against SICK AG shall be-

come void.

1.4

General protective notes and
protective measures

Safety position switches serve the purpose of pro-

tecting individuals. Tampering or incorrect installa-

tion may result in severe personal injury.

Do not override safety position switches (by

bridging contacts), turn them from their pro-

tective position, remove them or defeat

them in any other way.

2

Mounting

Mounting is only allowed to be performed by

qualified safety personnel.

Mount the safety position switch such that

It is difficult to access by operating personnel

when the protective equipment is open.

it can be inspected and replaced.

Do not use the safety position switch as a

mechanical stop.

The safety position switch must be adequa-

tely secured against movement.

In order to meet these requirements,

the mounting components must be reliable and

require a tool to be released,

the use of elongated holes must be restricted to

the initial settings,

the roller lever must be mounted on the motor

shaft with a positive fit.

Assemble safety switch with 2 bolts M4 and

tighten screws at 2.5–3 Nm.

Take note of the data in the switch-path diagram

(Fig. 1) when mounting the radial cam.

2.1

Change actuator entry direction

Undo screws on actuating head.

Set direction required (4 x 90°).

Tighten screws to 0.4–0.45 Nm.

2.2

Protection from environment

To ensure consistent, fault-free function of the

safety switch, debris must not be allowed to enter

the switch.
Mask the nameplate before applying paint.

3

Electrical installation

The electrical connection is only allowed to

be made by qualified safety personnel.

Install cable connector M20 with the required IP

protection.

See connection switching position diagram

(Fig. 1).

Operate all contact pairs within the same

voltage range.

Connect all live parts on one side of the

contact block.

Tighten clamping screws to 0.9 ... 1.0 Nm.

Check sealing at conduit entry.

Close switch lid and tighten screws.

4

Commissioning

4.1

Tests before the first commission-
ing

Mechanical function test

Test the movement of the roller lever/roller tap-

pet for smoothness of operation.

Electrical function test

Actuate the roller lever/roller tappet and test the

switching function.

Electrical performance test in safety switching

circuits.

Close safety guard.

Turn on machine.

Check whether opening the safety guard

stops the machine.

Turn off machine.

Open safety guard.

Machine must not start while safety guard is

open!

4.2

Regular technical inspections

To ensure consistent, fault-free function of the

safety switch, inspections should be performed on

a regular basis.
The machine operator should carry out the follow-

ing checks each day or before each shift:

switch functioning properly?

no evidence of tampering?

Regularly according to the machine maintenance

schedule by qualified safety personnel:

switch functioning properly?

all components safely installed?

deposits and wear?

conduit entry sealed?

loose cable connections or connectors?

If signs of damage or wear are detected, the

complete switch must be replaced.
Do not replace individual components or

assemblies!

The complete safety position switch must be

replaced after 10 x 10

6

switching operations.

5

Technical data

5.1

General specifications

Housing material

Glass-fibre-reinforced thermoplastic

Environmental protection to IEC 60529

IP 66

Mechanical service life

10 x 10

6

switching operations

B10

d

2x 10

6

switching operations with low load as per

EN ISO 13849-1

Starting speed min.

0.1 m/min.

Starting speed max.

15 m/min

Ambient temperature

–25 ... +80 °C

Connection type

1 x M20

Switching principle

Contact element

Contact elements positively guided NC

contacts/NO contacts

2/1

Max. surge voltage U

imp

2500 V

Rated insulation voltage U

i

250 V

Utilisation category to IEC 60947-5-1

AC 15: 240 V/3 A

DC 13: 24 V/3 A

Switching voltage (minimum)

5 V DC

Switching current (minimum) at 5 V DC

25 mA

Short-circuit protection

F 15/15 A

Frequency of use (maximum)

6000/h

Wire cross-section

0.75 mm

2

... 2.5 mm

2

Actuation force for i10P

6 N

Actuation torque for i10R

14 Ncm

Breakaway torque for screws

Mounting screws housing

Cover screw

Jam screws contacts

Head screws

Fixing screw for roller lever

(i10R only)

3.0 Nm

0.45 Nm

1.0 Nm

0.45 Nm

1.5 Nm

Summary of Contents for i10P

Page 1: ...en Verletzungen von Personen f hren Sicherheitspositionsschalter d rfen nicht umgangen Kontakte berbr ckt weg gedreht entfernt oder auf andere Weise unwirksam gemacht werden 2 Montage Die Montage darf...

Page 2: ...g Der Sicherheitspositionsschalter i10R oder i10P wurde gem den folgenden Richtlinien hergestellt die Maschinenrichtlinie 98 37 EG ab dem 29 12 2009 die Maschinenrichtlinie 2006 42 EG Hinweis Die EG K...

Page 3: ...nop ration nels de quelque fa on que ce soit 2 Montage Le montage doit tre effectu exclusivement par un personnel qualifi et habilit Implanter l interrupteur de position de sorte que le personnel util...

Page 4: ...n CE de conformit l interrupteur de position de s curit i10R ou i10P ne a t fabriqu conform ment aux directives suivantes la directive machine 98 37 CE partir du 29 12 2009 la directive machine 2006 4...

Page 5: ...tches by bridging contacts turn them from their pro tective position remove them or defeat them in any other way 2 Mounting Mounting is only allowed to be performed by qualified safety personnel Mount...

Page 6: ...P 6 EC declaration of conformity The safety position switch i10R or i10P was manufactured in conformity with the following directives and standards the machinery directive 98 37 EC from 29 12 2009 the...

Page 7: ...interruttore di posizione di sicurezza in modo che gli operatori non possano accedervi che difficil mente quando il dispositivo di protezione aper to siano possibili il controllo e la sostituzione de...

Page 8: ...re di posizione di sicurezza i10R o i10P realizzato in conformit alle disposizioni conte nute nelle direttive del consiglio dei ministri la Direttiva Macchine 98 37 CE a partire dal 29 12 2009 la Dire...

Page 9: ...otection device to protect people at the machi ne system The protection device stops the condition cau sing a danger and or prevents the machine system from starting up This protection device may requ...

Page 10: ...e servicio son una traducci n de las instrucciones de servicio originales PELIGRO Lea detenidamente estas indicaciones de seguridad y las instrucciones de servicio del dispositivo de protecci n Tenga...

Page 11: ...installation et sa premi re mise en marche doivent tre effectu s par un personnel habilit Le dispositif de protection ne doit tre utilis sur la machine l installation que par des personnes habilit es...

Page 12: ...t beveiligingssysteem kunnen aanvullen de beveiligingssystemen en maatregelen vereist zijn Het veiligheidsniveau van het beveiligingssysteem moet minstens voldoen aan het niveau van eisen van de machi...

Page 13: ...ispozitivului de siguran trebuie s corespund cel pu in nivelului de cerin e al ma inii instala iei nivel de siguran al dispozitivului de protec ie vezi Manualul de utilizare Dispozitivul de protec ie...

Page 14: ...ningen Skyddsanordningen m ste f rst monteras p maski nen anl ggningen och tas i drift av sakkunniga personer enligt bruksanvisningen Skyddsanordningen f r endast anv ndas p maskinen anl ggningen av s...

Reviews: