Function
Description
6
Minimum height value of the surface of the inspection object within the search
rectangle.
7
Maximum height value of the surface of the inspection object within the search
rectangle.
8
Minimum outer diameter of the circle.
7.5.5.5
Align PA
page
The
Align PA
page can be used to determine the position and orientation of objects on
the surface (pads, etc.). This can then be used, for example, to align areas that are not
to be checked.
First, an object is searched for that corresponds to the settings (minimum and maxi‐
mum area, minimum and maximum height above the base height applicable in the
search region). The (geometric) center of gravity and the orientation of the major axis of
the found object then give the origin and the orientation of the coordinate system.
7.5.5.5.1
Common
tab
The configuration options in the
Common
tab are the same for the alignment types
3E
,
CC
and
PA
).
7.5.5.5.2
Options
tab
The
Options
tab is used to set the display or maintenance parameters.
Figure 53: Alignment PA, Options tab
Function
Description
1
Display the surface used to determine the origin and orientation of the coordi‐
nate system in the image.
2
Show the region that is not in use.
3
Show the alignment coordinate system.
4
Parameters for development. This can be used to display the debug region used
for system maintenance.
5
This option supports system maintenance and further development.
NOTE
This option is not required in check mode. Since this option uses up
additional time, it should always be deactivated in inspection mode.
7.5.5.5.3
Parameters
tab
All the parameters provided on the
Parameters
tab are specified as an interval with a
lower limit and an upper limit, except for the Opening Rect Length parameters.
7
OPERATION
56
O P E R A T I N G I N S T R U C T I O N S | FOS-HVS
8027445/V1-0/2022-06-15 | SICK
Subject to change without notice