![SICK FOS-HVS Duo 1600 Operating Instructions Manual Download Page 77](http://html.mh-extra.com/html/sick/fos-hvs-duo-1600/fos-hvs-duo-1600_operating-instructions-manual_1264362077.webp)
7.5.8.2
FOD
(Foreign Object Detection) page
7.5.8.2.1
Common
tab
Figure 82: FOD, Common tab
Function
Description
1
Input field for name assignment.
2
Select
Basic ROI
from the drop-down menu of available regions to be used as the
basis for the inspection.
Apply the selection by clicking the
Select
button.
After clicking the
GetROI
button, the ROI is displayed.
3
Apply the selection.
4
Enable/disable the setup inspection (enabled by default).
NOTE
If the search region is not displayed in the image, the zoom factor may be
too large and the region is outside the display area. Decrease the zoom factor to view
and move the region.
7.5.8.2.2
Options
tab
The
Options
tab is used to configure display or maintenance parameters.
Figure 83: FOD, Options tab
Function
Description
1
Show region (enabled by default).
2
Display foreign objects found.
3
Display the region where foreign objects are searched for.
4
Parameters for development. This can be used to display the debug region used
for system maintenance.
OPERATION
7
8027445/V1-0/2022-06-15 | SICK
O P E R A T I N G I N S T R U C T I O N S | FOS-HVS
77