Function
Description
7
This option supports system maintenance and further development.
NOTE
This option is not required in check mode. Since this option uses up
additional time, it should always be deactivated in inspection mode.
7.5.7.4.3
Segmentation
tab
The following configuration options are available in the
Segmentation
tab.
Figure 76: ROI Seal, Segmentation Tab
Function
Description
1
Minimum height difference (in mm) between the rubber seal and the surface of
the inspection object.
2
Maximum height value (in mm) for the surfaces on the inspection object on
which a rubber seal is installed.
3
Extension of the rubber seal in the X direction, minimum value (in mm).
4
Extension of the rubber seal in the X direction, maximum value (in mm).
5
Extension of the rubber seal in the Y direction, minimum value (in mm).
6
Extension of the rubber seal in the Y direction, maximum value (in mm).
7
Threshold value for shadowing (from laser or camera view or due to adjacent
foreign objects). This value is needed to handle artifacts at the transitions from
the rubber seal to the surface (
NoData
regions).
7.5.7.4.4
Mask
tab
The
Mask
tab is used to adjust the inspection region for surface checks to avoid false
detections.
Figure 77: ROI Seal, Mask tab
OPERATION
7
8027445/V1-0/2022-06-15 | SICK
O P E R A T I N G I N S T R U C T I O N S | FOS-HVS
73
Subject to change without notice