Operating instructions
Chapter
11
Flexi Classic
8011509/YPP0/2015-10-26
© SICK AG • Industrial Safety Systems • Germany • All rights reserved
99
Subject to change without notice
Technical specifications
Minimum
Typical
Maximum
Response time (EN)
–
–
13 ms
0 / 0.5 / 1 /1.5 / 2 / 2.5 / 3 / 3.5 / 4 / 5 s
0 / 5 / 10 / 15 / 20 / 25 / 30 / 35 / 40 / 50 s
Time delay (adjustable)
0 / 0.5 / 1 / 1.5 / 2 / 2.5 / 3 / 3.5 / 4 / 5 min
General system data
Weight (without packaging)
–
0.18 kg
–
Electrical safety
Class III
Interference resistance
EN 61
000-6-2
Radiated emission
EN 61
000-6-4
Operating data
Ambient operating temperature
(UL/CSA: ambient temperature)
–25 °C
–
55 °C
Storage temperature
–25 °C
–
70 °C
Air humidity
10
% to 95
%, non-condensing
Climatic conditions
EN 61
131-2
Mechanical strength
Vibration
EN 61
131-2
Vibration resistance
5-500 Hz/5 grms (EN 60
068-2-64)
Terminal and connection data
Single-wire or fine-wire
1 × 0.14 mm² to 2.5 mm² or
2 × 0.14 mm² to 0.75 mm²
Fine-wire with terminal crimps to
EN 46
228
1 × 0.25 mm² to 2.5 mm² or
2 × 0.25 mm² to 0.5 mm²
Insulation stripping length
–
–
8 mm
Maximum tightening torque
–
–
0.6 Nm
For UL 508 and CSA applications
UE410-xx
3
…, UE410-xxx
3
…
– Connection cross-section
AWG 30-12
(only use 60/75 °C copper flexible wire)
– Tightening torque
5-7 lb
⋅
in
UE410-xx
4
…, UE410-xxx
4
…
– Connection cross-section
AWG 30-12
(only use 60/75 °C copper flexible wire)
18)
Cascading subsystems.