![SICK Flexi Classic series Operating Instructions Manual Download Page 55](http://html.mh-extra.com/html/sick/flexi-classic-series/flexi-classic-series_operating-instructions-manual_1264302055.webp)
Operating instructions
Chapter
3
Flexi Classic
8011509/YPP0/2015-10-26
© SICK AG • Industrial Safety Systems • Germany • All rights reserved
55
Subject to change without notice
Product description
Switch
position
Input A
Input B
3
AND
2 × dual-channel, cross-circuit
detection, synchronous time
monitoring 1500 ms
X1-I1
X2-I2
X3-I3
X4-I4
X5-I5
X6-I6
X7-I7
X8-I8
4
AND
2 × dual-channel, cross-circuit
detection
X1-I1
X2-I2
X3-I3
X4-I4
X5-I5
X6-I6
X7-I7
X8-I8
5
AND
2 × dual-channel, cross-circuit
detection, synchronous time
monitoring 1500 ms
X1-I1
X2-I2
X3-I3
X4-I4
X5-I5
X6-I6
X7-I7
X8-I8
AND
2 × dual-channel,
semiconductor
OSSD1
Sensor
-I1
OSSD2
Sensor
-I2
OSSD1
Sensor
-I3
OSSD2
Sensor
-I4
OSSD1
Sensor
-I5
OSSD2
Sensor
-I6
OSSD1
Sensor
-I7
OSSD2
Sensor
-I8
AND
2 × dual-channel, three-wire
+U
B
-I1
+U
B
-I2
+U
B
-I3
+U
B
-I4
+U
B
-I5
+U
B
-I6
+U
B
-I7
+U
B
-I8
6
AND
2 × single-channel
+U
B
-I1
+U
B
-I2
+U
B
-I3
+U
B
-I4
+U
B
-I5
+U
B
-I6
+U
B
-I7
+U
B
-I8
OR
2 × dual-channel,
semiconductor
OSSD1
Sensor
-I1
OSSD2
Sensor
-I2
OSSD1
Sensor
-I3
OSSD2
Sensor
-I4
OSSD1
Sensor
-I5
OSSD2
Sensor
-I6
OSSD1
Sensor
-I7
OSSD2
Sensor
-I8
OR
2 × dual-channel,
three-wire
+U
B
-I1
+U
B
-I2
+U
B
-I3
+U
B
-I4
+U
B
-I5
+U
B
-I6
+U
B
-I7
+U
B
-I8
7
OR
2 × single-channel
+U
B
-I1
+U
B
-I2
+U
B
-I3
+U
B
-I4
+U
B
-I5
+U
B
-I6
+U
B
-I7
+U
B
-I8
8
Bypass
1 × dual-channel, cross-circuit
detection
X1-I1
X2-I2
I3 n.c.
I4 n.c.
X5-I5
X6-I6
I7 n.c.
I8 n.c.
9
Input supplement
–
Function as for input B
Function as for input A
With AND logic, unused inputs must be bridged to logical “1” (e.g. X4-I4, U
B
-I4)!
Tab. 24: Connection of sensors to the UE410-8DI