![SICK Flexi Classic series Operating Instructions Manual Download Page 109](http://html.mh-extra.com/html/sick/flexi-classic-series/flexi-classic-series_operating-instructions-manual_1264302109.webp)
Operating instructions
Chapter
11
Flexi Classic
8011509/YPP0/2015-10-26
© SICK AG • Industrial Safety Systems • Germany • All rights reserved
109
Subject to change without notice
Technical specifications
Minimum
Typical
Maximum
Output circuit (Y14, Y24)
Type of output
Non-isolated N/O contact, positively guided,
current-limited
Number of N/O contacts Y14/24
UE410-2RO
–
1
–
UE410-4RO
–
2
–
Output voltage
16 V DC
24 V DC
30 V DC
Output current
–
–
75 mA
Load capacity
–
–
200 nF
General data
Electrical isolation
Supply circuit-input circuit
No
Supply circuit-output circuit
Yes
Input circuit-output circuit
Yes
Weight (without packaging)
UE410-2RO
0.16 kg
UE410-4RO
0.19 kg
Operating data
Ambient operating temperature
(UL/CSA: ambient temperature)
–25 °C
–
55 °C
Storage temperature
–25 °C
–
70 °C
Air humidity
10
% to 95
%, non-condensing
Climatic conditions
EN 61
131-2
Mechanical strength
Vibration resistance
5-150 Hz/1 G (EN 60
068-2-6)
10-500 Hz/3 G
rms
(EN 60
068-2-64)
Shock resistance
Continuous shock
10 g, 16 ms (EN 60
068-2-27)
Single shock
30 g, 11 ms (EN 60
068-2-27)
33)
The total output current is limited. Maximum total current for all relay modules on Y14 and Y24 is I < 400 mA.