Module
Contents
Description
Type
Size
Relative address
20
Device
No process data
Alignment laser
Parameter
1 byte
0.0
Measuring laser
Parameter
1 byte
1.0
Heating
Parameter
1 byte
2.0
Heating switch-on temp. [C]
Parameter
1 byte
3.0
Display language
Parameter
1 byte
4.0
Display units
Parameter
1 byte
5.0
Display contrast [%]
Parameter
1 byte
6.0
Display brightness [%]
Parameter
1 byte
7.0
Display orientation
Parameter
1 byte
8.0
21
Basic measurement settings
No process data
Meas. cycle time
Parameters
1 byte
0.0
Measurement direction
Parameters
1 byte
1.0
Rain and snow filter
Parameter
1 byte
2.0
Fog filter
Parameter
1 byte
3.0
23
Exp. meas. settings
No process data
Echo selection
Parameter
1 byte
0.0
Distance range from [mm]
Parameter
4 bytes
1.0
Distance range to [mm]
Parameter
4 bytes
5.0
Signal level range from [digit]
Parameter
4 bytes
9.0
Signal level range to [digit]
Parameter
4 bytes
13.0
Distance filter
Parameter
1 byte
17.0
Averaging filter depth [cycle]
Parameter
4 bytes
18.0
Speed filter depth [cycle]
Parameter
4 bytes
22.0
No echo suppression time [cycle]
Parameter
4 bytes
26.0
No echo behavior
Parameter
1 byte
30.0
No echo substitute distance [mm]
Parameter
4 bytes
31.0
No echo substitute speed [mm/s]
Parameter
4 bytes
35.0
Error substitute distance [mm]
Parameter
4 bytes
39.0
Error substitute speed [mm/s]
Parameter
4 bytes
43.0
25
Offset
No process data
Distance offset [mm]
Parameter
4 bytes
0.0
26
Preset
No process data
Preset [mm]
Parameter
4 bytes
0.0
27
Dynamic Preset Trigger
Output
1 byte
0.0
3
PRODUCT DESCRIPTION
30
O P E R A T I N G I N S T R U C T I O N S | DT1000 PROFIBUS DP and DL1000 PROFIBUS DP
8024560/1A19/2021-06-30 | SICK
Subject to change without notice