Operating Instructions
Chapter
4
CLV 490 Bar Code Scanner
8 008 796/0000/25-06-2002
©
SICK AG · Division Auto Ident · Germany · All rights reserved
4-3
Installation
4.2.6
Mounting accessories
The CLV is secured in position using the two tapped blind holes (M 6) above the electrial
shows the location of the threads near the line scanner.
The dimensions of the CLV housing are shown in
to
The CLV can be mounted using the SICK bracket:
•
Mounting bracket, single no. 2 013 824
•
Articulated bracket (2 x mounting bracket, single) no. 2 018 435
•
Quick-clamping device no. 2 016 110
The brackets are designed to support a variety of mounting positions and alignments in two
planes.
shows two mounting examples.
The elongated holes in the mounting bracket no. 2 013 824 and in the articulated bracket
no. 2 018 435 allow the CLV to be adjusted with a freedom of rotation of
±
15
°
.
The dimensions of the mounting brackets are shown in
Chapter 10.14 Dimensioned draw-
ings of the accessories, Page 10-75
Fig. 4-2:
Line scanner: position of the securing threads on the CLV
33.4
10
10
10
38.5
12
56
21
78
43.3
EN 60825-1: 1994 +
A1
1 : 1996
Max. output radiation:
Pulse duration:
Emitted wavelength:
2,8
111
650
mW
us
nm
2,8
56
650
mW
us
nm
CLASS II LASER PRODUCT
Max. Output:
Pulse duration:
W
avelength:
Compiles with 21 CFR 1040.10
Drilled hole,
∅
3.6 mm,
6 mm deep
Blind hole thread, M 6,
7 mm deep
Fig. 4-3:
Line scanner: Mounting possibilities of the CLV
Quick-clamping
device
Mounting
bracket