Operating Instructions
Chapter
4
CLV 490 Bar Code Scanner
8 008 796/0000/25-06-2002
©
SICK AG · Division Auto Ident · Germany · All rights reserved
4-11
Installation
1.
Mount the reading pulse sensor.
2.
Connect the reading pulse sensor to the "Sensor" switching input of the CLV via the
AMV/S 60 Connection Module (see
Chapter 5.5.7 Connecting the switching inputs,
).
3.
Connect the CLV to the AMV/S 60 Connection Module and switch on the power supply
to the module (see
Chapter 5.5.3 Connecting the supply voltage, Page 5-13
After it has started, the CLV confirms that the self-test was successfull and switches to
Reading mode ("Device Ready" LED lights up).
4.
Connect the PC to the terminal interface of CLV via a RS 232 data connection cable
using the internal 9-pin "Service" plug of the AMV/S 60 (see
5.
Start Windows and the "CLV-Setup" program (see
Chapter 10.6.3 Starting CLV-Setup,
).
6.
From the V
IEW
menu, choose R
EADING
M
ODE
.
The Terminal Emulator is launched. The CLV is in Reading mode (default: SMART
decoder).
Monitor the reading result during each of the subsequent steps!
Line scanner with oscillating mirror:
In default setting, the CLV deflects the scan line (default setting) about the fixed position
CW = 50 with a frequency of 1 Hz at a max. angle of
±
20
°
(
±
40 CW).
50 CW corresponds to an angle of emergence of 105
°
.
7.
Move objects with bar codes into the CLV reading field manually under realistic conditi-
ons and check whether the reading result and trigger pulse are correct.
8.
Repeat the procedure with the conveyor switched on. Check whether the reading
procedure is synchronized with the objects.
Parameterizing an external sensor as a trigger source:
These settings are not required if the CLV is operated with the default configuration.
1.
Choose the D
EVICE
C
ONFIGURATION
tab.
2.
In the R
EADING
T
RIGGER
M
ODE
section click the option S
ENSOR
I
NPUT
(A
CTIVE
H
IGH
).
3.
Download the settings to the CLV by clicking
in the toolbar.
The D
OWNLOAD
P
ARAMETERS
dialog box is then displayed.
4.
Confirm the dialog box by choosing P
ERMANENT
.
The CLV operates with the "Sensor" switching input as an external trigger source. The
reading pulse starts when the input is energized (high).