Operation
6.7
Switching off the CLV
1.
If the parameter set was modified in CLV-Setup or was only stored temporarily in CLV
via a download, the parameter set must be stored permanently in the CLV by choosing
the P
ERMANENT
storage option.
2.
Save the parameter set as a configuration file "*.scl" in CLV-Setup.
3.
Switch off the power supply of the AMV/S 60 or unplug both of the CLV’s connecting
cables from the connection module.
The last parameter set stored permanently in the CLV remains valid.
We recommend that you print out the configuration file in order to archive the parameter set.
1.
Click
in the toolbar.
The P
RINT
FILE
dialog box is then displayed.
2.
Enter a comment in the input field in order to assign the printout to the CLV.
Confirm your entry with OK.
The P
RINT
dialog box for configuring the printer is then displayed.
3.
Make the necessary entries in the dialog box and confirm these.
CLV-Setup prints out the current configuration file in the form of a table.