Operating Instructions
Chapter
10
CLV 490 Bar Code Scanner
8 008 796/0000/25-06-2002
©
SICK AG · Division Auto Ident · Germany · All rights reserved
10-63
Appendix
4. Set the evaluation properties: C
ODE
C
ONFIGURATION
tab
¾
Set the following parameters:
- Codes:
2/5 Interleaved; deactivate all other code types!
(remove check)
- Number of Codes:
Minimum 1
,
Maximum 1
- Code Positions:
deactivate
(remove check)
- Decoder:
SMART/Standard
¾
Click on the E
DIT
CODES
button.
¾
Set the following parameters on the 2/5 I
NTERLEAVED
tab in the dialog window:
- Code Length:
Fixed
; length 1:
14 characters
- Multiple Reads for Length 1:
3
- Check Digit Test for Length 1:
mod 10
- Transmit Check Digit:
activate
- Transmit Leading Zero:
activate
¾
Confirm dialog box with ”OK”.
Fig. 10-53: Parameterization example: settings on the "Code Configuration" tab
Fig. 10-54: Parameterization example: "2/5 Interleaved" tab