Operating Instructions
CLV 490 Bar Code Scanner
10-60
©
SICK AG · Division Auto Ident · Germany · All rights reserved
8 008 796/0000/25-06-2002
Appendix
¾
Set the following parameters on the O
PTIMIZATION
tab (
– Delay of focus change
Timeout:
50 ms
Hysteresis:
50 mm
– Distance Measurement:
active
– Source of Distance information
: internal
– Smooth filter active:
active
Length:
3
¾
Confirm the dialog window by clicking "OK".
2. Setting up the autofocus function (Part 2): D
EVICE
C
ONFIGURATION
tab
Fig. 10-48: Parameterization example: "Edit Auto Focus/Optimizations" dialog window
Fig. 10-49: Parameterization example: Buttons on the "Device Configuration" tab