Chapter
6
Operating Instructions
CLV 490 Bar Code Scanner
6-32
©
SICK AG · Division Auto Ident · Germany · All rights reserved
8 008 796/0000/25-06-2002
Operation
6.5.11
Executing CLV functions interactively
CLV-Setup enables a number of CLV functions to be executed interactively. CLV-Setup
prompts the user to carry out specific actions and provides information on the progress of
the function being executed.
The following functions are available:
•
Background teach-in/reset (to default)
•
Percentage evaluation
•
Show CP-limits
•
Adjustment mode
•
Copy parameter memory
•
Analyze scanner network
¾
Choose CLV 490, D
EVICE
F
UNCTIONS
and the desired function
– or –
press the [F2] key.
The E
XECUTE
D
EVICE
F
UNCTIONS
dialog box is then displayed.
Choose the desired function in the E
XECUTE
menu in the menu.
CLV-Setup starts the function and, where appropriate, prompts the user to carry out the
necessary actions.
shows an example of the dialog box that appears after Show CP-limits has been
started.
Fig. 6-16:
CLV-Setup: Dialog box for executing Show limits