FOV
3
1.3 Mpx image sensor
1
1.9 Mpx image sensor
2
FOV
3
Figure 8: Resolution-dependent field of view geometries
1
Device with image sensor 1.3 Mpx
2
Device with image sensor 1.9 Mpx
3
Field of view
Align the device taking into consideration the field of view (
) and the application circumstances (
see "Installation requirements", page 26
Mounting the device
Perform one of the following steps:
•
Mount the device on a customer-supplied mounting system using at least 2 M5
screws of a suitable length. Screw the screws no more than 5 mm into the tapped
blind holes or sliding nuts of the device.
°
To do this, either use all 4 threaded mounting holes on the rear of the device
or, alternatively, use the two M5 sliding nuts in the lateral slots.
•
Attach the separately-ordered, optional SICK mounting system using the two slid‐
ing nuts on the device.
5
MOUNTING
38
O P E R A T I N G I N S T R U C T I O N S | Lector63x Flex C-mount and S-mount
8018071/16XD/2020-05-06 | SICK
Subject to change without notice