The device can be aligned in the X- and Y-axes.
•
The mounting system must be able to bear the weight of the device and connect‐
ing cables without shock.
•
In mounting situations with strong vibrations, it may be necessary to provide shock
mounts.
•
Device mounting options using the four tapped blind holes or two sliding nuts
must be provided.
5.4
Mounting the lens unit
NOTE
This mounting step is only required if the optics accessory or the “basic device” device
type has been ordered.
You can find further information on pre-mounted devices on the Internet at:
.
NOTICE
Risk of damage due to electrostatic discharge!
Electrostatic discharge from the human body may damage parts of the illumination unit
or the camera housing.
The illumination variants for lenses with a focal length of 12
mm or 16
mm do not fea‐
ture any plastic lenses in front of the LEDs in the round recesses.
■
Take the necessary ESD precautions when assembling the device.
■
Do not insert your fingers into the recesses.
■
Do not touch the open contacts of the electrical connection for the illumination
unit on the camera housing.
NOTE
Possible impairment of image quality!
Dust and fingerprints on optical boundary surfaces can decrease the image quality and
decoding performance of the device.
b
Ensure a dust-free and dry environment when mounting components.
b
Do not touch the image sensor (CMOS) in the light inlet opening of the device or
the glass lenses at either end of the lens unit.
Auxiliary equipment required
•
SW 2 hexagon key (included with delivery)
•
SW 5 socket wrench, Recommendation: as a torque wrench for 65 Ncm
MOUNTING
5